Inverter Size Calculator

List your appliances with running and starting watts and hours, and get the inverter size, VA, battery bank in Ah, DC current and a load table to print.

Działa w Twojej przeglądarce. Twoje pliki nigdy nie opuszczają urządzenia. Zobacz, jak to sprawdzić

…

Jak to zrobić

  1. 1
    List your appliances

    Add appliances from the library or blank rows, with quantity, running watts, starting watts and hours per day.

  2. 2
    Mark motors

    Tick Motor for fridges, pumps, fans and compressors and untick any rows you will not run.

  3. 3
    Set the assumptions

    In Inverter and battery choose the margin, start-up assumption and power factor.

  4. 4
    Size the battery

    Pick backup hours or a full day, the battery voltage, depth of discharge and inverter efficiency.

  5. 5
    Read the result

    Check the inverter size, surge peak, battery bank in Wh and Ah, DC current and sine-wave advice.

  6. 6
    Print or export

    Print the load table with the working or export it as CSV.

O tym narzędziu

An inverter that is too small trips when the fridge compressor starts; one that is too large costs more and wastes power at idle. This calculator sizes it from the loads you actually plan to run. Build a load table from a library of twenty common appliances or blank rows: quantity, running watts, starting (surge) watts, hours per day and whether it has a motor or compressor. Untick a row to see what happens without it. The tool adds the running load, works out the start-up peak (one motor starting at a time, or everything at once), applies a safety margin and picks the next standard inverter size, with the apparent power in VA. It then sizes the battery bank for a number of backup hours or a full day of use, allowing for depth of discharge and inverter efficiency, and gives the DC current at 12, 24 or 48 V. Advice on pure sine versus modified sine output and a bar chart of loads complete the picture.

Running watts and surge watts

Every appliance has a running power, printed on the rating plate or found as volts times amps. Motors and compressors also draw a short starting surge, often two to three times their running power, for a fraction of a second. An inverter has two ratings to match: continuous power for the running load and surge power for those starts. The calculator assumes by default that only one motor starts at a time, which is normal at home, and adds the largest single extra starting power to the running total.

Margin and standard sizes

Running an inverter at its full continuous rating makes it hot and loud and leaves no room for new loads. A margin of 20-30 % is common. The result is rounded up to a standard size between 150 W and 15 kW, and the VA figure divides by the power factor for models rated in VA.

Battery bank

Battery energy is the running load times the backup hours, or the daily sum of watts times hours from the table. Dividing by the usable depth of discharge (about 0.5 for lead-acid, 0.8-0.9 for LiFePO4) and by the inverter efficiency gives the bank size in Wh, and dividing by the system voltage gives Ah. The DC current shows why bigger systems use 24 or 48 V: the same power at a higher voltage needs thinner cables.

Pure or modified sine

When the table contains motors, compressors or electronics such as computers, TVs or a CPAP machine, the calculator recommends a pure sine wave inverter. Modified sine output can make motors hum and run hot and can disturb sensitive devices.

Worked example

Six 10 W LED bulbs, two 75 W fans, a 150 W fridge, an 80 W TV and a 12 W router draw 452 W. The fridge's start adds 450 W, so the peak is 902 W. With a 25 % margin the continuous need is 565 W, so a 600 W pure sine inverter (750 VA at PF 0.8) with at least 902 W surge fits. For 4 hours of backup the loads use 1,808 Wh; at 80 % depth of discharge and 90 % efficiency the bank needs 2,511 Wh, which is about 105 Ah at 24 V, drawing about 21 A.

Limits

Appliance values in the library are typical and real products vary, so read your rating plates. Surge figures for compressors and pumps can be higher than listed, and some inverters handle surges for only a few milliseconds. The battery figure ignores battery ageing, temperature and charging from solar or the grid. Have a qualified electrician install inverters connected to house wiring; this tool is not an installation design.

Przykład z rozwiązaniem

452 W running, 902 W peak → 600 W inverter; 4 h backup at 24 V → about 105 Ah bank, 21 A DC.

W skrócie

Najczęstsze pytania

How do I calculate what size inverter I need?

Add the running watts of everything you will use at the same time, add a 20-30 % margin and round up to a standard size. Check that the inverter's surge rating covers the largest motor start.

What are surge watts?

The short burst of power a motor or compressor draws when it starts, often two to three times its running watts. Fridges, pumps, air conditioners and washing machines all have it.

How many batteries do I need for my inverter?

Multiply the watts by the backup hours to get Wh, divide by the usable depth of discharge and the inverter efficiency, then divide by the battery voltage to get Ah.

Do I need a pure sine wave inverter?

For fridges, fans, pumps, computers, TVs and medical devices, yes. Modified sine inverters are cheaper but can make motors run hot and noisy and upset electronics.

Should I use a 12 V, 24 V or 48 V battery bank?

As a rough guide, 12 V up to about 1.2 kW, 24 V up to about 3 kW and 48 V above that. Higher voltage means lower current and thinner cables.

Can I print the load table?

Yes. Print load table gives the appliance list with running, starting and daily energy totals plus the sizing steps, and CSV exports it for a spreadsheet.