Pneumatic Cylinder Air Consumption Calculator
Add every pneumatic cylinder on a machine with bore, rod, stroke, pressure, cycles per minute, single or double acting and tubing, and get push and pull forces, free air per cycle and per minute, the system demand with utilisation, leakage and reserve, the compressor delivery in NL/min and scfm, compressor power and running cost, and the air receiver volume, with CSV and a printed report.
Berjalan dalam pelayar anda. Fail anda tidak pernah meninggalkan peranti. Lihat cara menyemaknya
…
Cara melakukannya
- 1List the cylinders
Add each cylinder type with bore, rod, stroke, number of cylinders and type.
- 2Set pressure and cycles
Enter the working pressure in bar gauge and the cycles per minute.
- 3Add tubing
Enter the inside diameter and length of the tube to each port.
- 4Set system factors
Adjust utilisation, leakage, reserve and the example specific power.
- 5Size the receiver
Enter the pressure band and the time the receiver must cover.
- 6Report
Print the demand report or export the cylinder table as CSV.
Tentang alat ini
Compressed air is one of the most expensive forms of energy in a factory, and the cylinders on a machine decide how much of it is used. Each stroke fills the cylinder chamber with air at the working pressure, and that air is exhausted to atmosphere at the end of the stroke. The swept volume of the push stroke is the piston area times the stroke; the pull stroke of a double-acting cylinder uses the annular area left after the piston rod, so it needs a little less air. A single-acting cylinder with a spring return uses air only on the push stroke. The tubing between the valve and the cylinder is filled and emptied every stroke too, so its volume is added. To compare this with a compressor rating, the volume at working pressure is turned into free air at atmospheric pressure by multiplying by the ratio (p gauge + 1.013) / 1.013. Multiplying by the cycles per minute and the number of identical cylinders gives normal litres per minute for each line of the table. The system tab adds them up, applies a utilisation factor for cylinders that do not all run at once, an allowance for leakage and a reserve for growth, and gives the free air delivery the compressor must supply in NL/min, m³/min and scfm. An example specific power turns that into compressor shaft power, yearly energy and cost. Two receiver sizes are given: the volume needed to cover the demand for a chosen time between the upper and lower pressures, V = Q t p0 / Δp, and an example rule for limiting compressor load and unload cycles.
Forces and sizing
Each cylinder shows the theoretical push force p × A and pull force p × (A − rod area), multiplied by a force efficiency for seal friction. The sizing tab works the other way: from the force you need, the working pressure and a load ratio (about 50 to 70 percent for moving loads, up to 85 percent for clamping) it finds the minimum bore and the next standard ISO 15552 or ISO 6432 bore, and adds that cylinder to the list.
Example values
Leakage, compressor specific power (kW per m³/min) and the receiver cycling rule vary widely between plants and machines; they are editable and labelled example. Replace them with your measured leakage and your compressor's data sheet.
Limits
The calculation assumes the cylinder completes its stroke and fills to the supply pressure, which is not true for very fast cycles, long thin tubes or undersized valves. It does not size valves, tubing or pressure drop in the distribution system, and it does not replace a compressed air audit. Receivers are pressure vessels and must meet the rules where you are.
Contoh berselesaian
A packing line has two pusher cylinders of 50 mm bore, 20 mm rod and 200 mm stroke at 12 cycles a minute, four 32 mm clamps with 50 mm stroke at 12 cycles, one 63 mm gate with 150 mm stroke at 6 cycles and two 20 mm single-acting ejectors with 25 mm stroke at 20 cycles, all at 6 bar gauge with 1.5 m of 4 mm tube per line. Each pusher uses 5.26 litres of free air per cycle and the pair 126.3 NL/min; the clamps take 37.4, the gate 38.4 and the ejectors 7.4 NL/min. The total is 209.5 NL/min. With 15 percent leakage and 25 percent reserve the compressor should deliver about 301 NL/min, or 10.6 scfm. At the example 6.5 kW per m³/min that is about 2 kW, 7,830 kWh a year over 4,000 hours, or about 1,958 at 0.25 per kWh. A receiver to cover the demand for one minute between 7.5 and 6.5 bar needs about 212 litres. Each pusher gives 1,178 N theoretical push force.
Ringkasnya
- Kategori: Kejuruteraan & pembinaan
- Berjalan dalam pelayar, tanpa pendaftaran, tanpa muat naik.
- Maklumat yang anda masukkan kekal pada peranti anda.
- Tersedia dalam bahasa Inggeris.
- Kandungan disemak kali terakhir:
- Sumber rasmi: Swept volume and free air at atmospheric pressure (ISO 8778 reference atmosphere), ISO 15552 and ISO 6432 cylinder bores, and the receiver sizing formulas in the Atlas Copco Compressed Air Manual
Soalan lazim
How do I calculate the air consumption of a pneumatic cylinder?
Multiply the piston area by the stroke for the push stroke, add the annular area times the stroke for the return of a double-acting cylinder, add the tube volume, then multiply by (p + 1.013) / 1.013 and by the cycles per minute.
What is free air delivery?
It is the volume of air a compressor delivers, expressed at the inlet (atmospheric) conditions. Cylinder demand must be converted to the same basis before you compare it with the compressor rating.
How much leakage should I allow?
Well maintained systems lose around 10 percent, many factories lose 20 to 30 percent. The tool uses an editable example; a leak survey gives the real figure.
Does the pull stroke use less air?
Yes, because the rod takes up part of the chamber. For a 50 mm bore with a 20 mm rod the pull stroke uses 84 percent of the push stroke air.
How big should the air receiver be?
It depends on how much demand it must cover and the pressure band. The tool gives V = Q t p0 / Δp for a chosen time and an example cycling rule; follow the compressor maker's recommendation as well.
Can it size the cylinder bore?
Yes. Enter the force, pressure and a load ratio on the sizing tab to get the minimum bore and the next standard size.
