Hydroponic Nutrient Mixer

Enter reservoir size, source water EC and your nutrient's label dose; get millilitres of each part for a target EC, a dated feeding schedule and top-up figures.

Berjalan dalam pelayar anda. Fail anda tidak pernah meninggalkan peranti. Lihat cara menyemaknya

…

Cara melakukannya

  1. 1
    Set the reservoir

    Enter the reservoir volume in litres or US gallons, your source water EC and your ppm meter scale.

  2. 2
    Add nutrient parts

    List each part with its label dose in ml per litre, in the order you add them.

  3. 3
    Calibrate once

    Mix one litre at full strength, measure EC and enter what a full dose adds.

  4. 4
    Mix to target

    Type the target EC and read the millilitres of each part for the whole reservoir.

  5. 5
    Plan the stages

    In Stage schedule set your start date, stage lengths and EC targets, then print or export the schedule.

  6. 6
    Top up

    In Top-up and dilution enter what is in the tank and what you add to predict the new EC.

Tentang alat ini

Nutrient labels give a dose per litre at full strength, but plants rarely want full strength all the time. Seedlings want a weak solution, fruiting tomatoes a strong one, and your tap water already carries some salts. This mixer works the other way round: you set the target electrical conductivity (EC) for the stage, enter what a full label dose adds to the EC and what your source water starts at, and it scales every nutrient part so the reservoir lands on the target. It converts EC to ppm on the three common meter scales, builds a dated schedule for each stage with doses for every part, and handles the everyday maths of topping up and diluting a reservoir that has drifted.

EC first, ppm second

Meters measure electrical conductivity in millisiemens per centimetre (mS/cm). A "ppm" or TDS reading is that conductivity multiplied by a factor the meter maker chose: 500 on many US meters (the NaCl scale), 700 on others (the KCl or Truncheon scale) and 640 on some European meters. The same solution can read 800, 1,024 or 1,120 ppm on three different pens. That is why the mixer works in EC and shows ppm on your chosen scale, and why feed charts written in ppm should always say which scale they use.

How the doses are scaled

Mix one litre at the full label rate, measure its EC and subtract your water's EC: that is the "EC a full dose adds", typically 1.5 to 2.5 mS/cm for a two-part grow formula. The dose fraction is then (target EC − water EC) ÷ EC per full dose, and each part's millilitres per litre are the label rate times that fraction. Because nutrient parts are usually designed to be used in a fixed ratio, the mixer keeps that ratio and only changes the strength. A warning appears if the result is more than 120 % of the label dose.

Stage schedule

The schedule lists stages with weeks, target EC and pH range, from seedlings through vegetative growth and flowering to a final low-EC week. Starting from your planting date it gives each stage's dates and the millilitres of every part for your reservoir, plus the number of full reservoir changes at your change interval. The defaults are examples; replace them with your nutrient maker's chart or the crop targets listed below the schedule.

Top-ups and dilution

Plants drink water faster than they take up salts, so EC usually creeps up between changes. The Top-up tab blends the current solution with what you add to predict the new EC, and tells you how many litres of plain water bring a strong reservoir down to the target.

Worked example

A 100 L reservoir with tap water at 0.2 mS/cm and a target of 1.6 needs an increase of 1.4. If a full label dose adds 2.0 mS/cm, the strength is 70 %. With parts A and B at 2 ml per litre on the label, each gets 1.4 ml per litre, or 140 ml for the tank. On a ×500 pen the target reads 800 ppm; on a ×700 pen it reads 1,120 ppm.

Limits

The linear scaling is an approximation; always confirm the final EC and pH with a calibrated meter. The tool does not formulate nutrients from raw salts, does not track individual elements and does not replace the nutrient maker's instructions.

Contoh berselesaian

100 L, water EC 0.2, target 1.6, full dose adds 2.0 → 70 % strength = 140 ml each of A and B; 800 ppm on ×500.

Ringkasnya

Soalan lazim

How do I convert EC to ppm?

Multiply EC in mS/cm by your meter's factor: 500 for NaCl-scale meters, 640 for Eutech meters and 700 for KCl-scale meters. An EC of 1.6 is 800, 1,024 or 1,120 ppm.

What EC should lettuce have?

Lettuce and leafy greens are usually grown at about 0.8 to 1.2 mS/cm. Fruiting crops such as tomatoes and cucumbers need much higher EC, often 2 to 3.5.

Why subtract my tap water EC?

Tap water already contains dissolved minerals. If it starts at 0.4 mS/cm and you want 1.6, the nutrients only need to add 1.2.

In what order do I add nutrient parts?

Add each part to the water separately and stir between them, in the order on the label. Never mix concentrated parts together, because calcium and sulphate or phosphate can precipitate.

How often should I change the reservoir?

Many growers change the whole reservoir every one to two weeks and top up in between. Smaller reservoirs and hot rooms need more frequent changes.

Does the tool adjust pH?

No. It shows a pH range per stage, but you need a pH meter and pH up or down solution to adjust it after mixing.

Percuma sepenuhnyaTiada bayaran, tiada pendaftaran
Fail kekal peribadiSemuanya berjalan dalam pelayar anda
Mudah dalam bahasa andaTersedia dalam banyak bahasa