Battery Charging Time Calculator
Enter capacity, charger rating and charge level, and see time to 80 %, to your target and to full, a charge curve and a table for several batteries.
Berjalan dalam pelayar anda. Fail anda tidak pernah meninggalkan peranti. Lihat cara menyemaknya
…
Cara melakukannya
- 1Add a battery
Use the example batteries or press + Battery and give it a name.
- 2Choose the chemistry
Pick Li-ion, LiFePO4, lead-acid or NiMH to load typical charging settings.
- 3Enter capacity and charge level
Type capacity in Ah, voltage, the start charge and the target.
- 4Enter the charger
Choose amps or watts and type the charger's rating.
- 5Read the times and charts
Check time to target, to 80 % and to full, the C-rate warning and the charge and current curves.
- 6Compare and export
Open Compare to see all batteries together, then export CSV or print.
Tentang alat ini
The simple rule "capacity divided by charger current" gives the wrong answer for most real batteries, because chargers slow down near the end. This calculator models it properly. Enter the battery's capacity in Ah, its voltage, the start and target charge in percent and the charger rating in amps or watts. Choose the chemistry (Li-ion or LiPo, LiFePO4, lead-acid, NiMH) and the tool fills in typical charge efficiency, the charge level where the constant-voltage phase begins and the cut-off current, all editable. It then shows the time to your target, to 80 % and to 100 %, the C-rate with a warning when it is high for that chemistry, the time spent at full current and the energy put in. Two charts draw charge level and current over time. Add more batteries to compare a phone, a car battery and a solar bank side by side.
Constant current, then constant voltage
Lithium batteries charge in two stages. In the constant-current (CC) stage the charger delivers its full current and the voltage rises. When the cell reaches its limit, about 4.2 V for Li-ion or 3.65 V for LiFePO4, the charger holds that voltage (CV) and the current tapers off until it falls to a cut-off, often 0.05C. The first 80 % or so is quick; the last 20 % can take as long again. Lead-acid chargers follow the same pattern as bulk and absorption stages.
How the time is calculated
In the CC stage, time = charge needed (Ah) ÷ (current × efficiency). The CV stage is modelled as a current that decays exponentially from the full current to the cut-off current while delivering the remaining charge. This matches the shape of real charge curves without needing a cell model. For NiMH the default is constant current to the end, as with -ΔV chargers.
Amps, watts and C-rate
Chargers are labelled in amps or watts. Watts are turned into amps at the battery voltage. The C-rate is current divided by capacity: 0.5C on a 10 Ah battery is 5 A. Most lead-acid batteries prefer 0.1-0.25C, LiFePO4 is often specified at 0.5C, and only some lithium cells accept more than 1C.
Worked example
A 10,000 mAh (10 Ah) power bank at 20 % charges from a 2 A input with 95 % efficiency. The CC stage to 80 % stores 6 Ah: 6 ÷ (2 × 0.95) = 3.16 h, about 3 h 09 min. The taper from 80 % to 100 % with a 0.5 A cut-off adds about 1.95 h, so the total is about 5 h 06 min, not the 4.2 h of the simple rule. A 60 Ah car battery at 20 % on a 6 A charger with 85 % efficiency reaches 80 % in about 7 h 04 min and full in about 11 h 48 min.
Limits
Real times depend on temperature, battery age, cable losses and how the charger and the device manage power; phones often slow charging when hot or when the screen is on. Efficiency and taper defaults are typical values. The energy figure is at the battery and excludes charger losses. Follow the manufacturer's charging limits; this is an estimate, not a safety rating.
Contoh berselesaian
10 Ah from 20 % at 2 A, 95 % efficient: 80 % in 3 h 09 min, full in about 5 h 06 min.
Ringkasnya
- Kategori: Kejuruteraan & pembinaan
- Berjalan dalam pelayar, tanpa pendaftaran, tanpa muat naik.
- Maklumat yang anda masukkan kekal pada peranti anda.
- Tersedia dalam bahasa Inggeris.
- Kandungan disemak kali terakhir:
- Sumber rasmi: Battery University BU-409 Charging Lithium-ion and BU-403 Charging Lead Acid
Soalan lazim
How do I calculate battery charging time?
For the constant-current part, divide the amp-hours needed by the charger current times the efficiency. Then add the slower constant-voltage taper at the end, which this calculator models for you.
Why is charging from 80 to 100 % so slow?
In the constant-voltage stage the charger holds the maximum cell voltage and the current falls steadily, so each extra percent takes longer than the one before.
What is a C-rate?
The charge or discharge current relative to capacity. 1C on a 5 Ah battery is 5 A and would charge it in about an hour if there were no taper or losses.
My charger is rated in watts. What do I enter?
Choose Watts as the charger unit and type the rating; the tool divides it by the battery voltage to get the current.
What efficiency should I use?
About 95 % for Li-ion, 97 % for LiFePO4, 80-85 % for lead-acid and around 70 % for NiMH. The chemistry choice fills these in and you can change them.
Can I compare several batteries?
Yes. Press + Battery for each one; the Compare tab lists all of them with times to 80 %, target and full, plus a bar chart, and exports to CSV.
