VPD Calculator for Growers
Enter room temperature, humidity and how much cooler the leaves are; get leaf VPD, the humidity that hits your stage target, a colour chart and a readings log.
브라우저에서 실행됩니다. 파일은 기기 밖으로 나가지 않습니다. 확인하는 방법 보기
…
사용 방법
- 1Enter conditions
Type the air temperature and relative humidity from your sensor, choosing °C or °F.
- 2Add the leaf offset
Measure leaves with an infrared thermometer and enter how much cooler they are than the air.
- 3Pick a stage
Choose a growth stage or set a custom target range in kPa.
- 4Read the advice
The calculator tab shows the zone, what to change and the humidity that hits the middle of the target.
- 5Check the chart
Open VPD chart to see which temperature and humidity pairs fall inside your target.
- 6Log readings
In Readings log press Log current reading at different times and export the CSV.
이 도구 소개
Relative humidity alone says little about how hard a plant is working to move water. Sixty percent humidity at 18 °C and sixty percent at 30 °C feel very different to a leaf. Vapour pressure deficit (VPD) combines temperature and humidity into one number in kilopascals: the gap between the water vapour the air could hold at leaf temperature and the vapour it actually holds. Growers in greenhouses, grow tents and indoor farms use it to keep transpiration in a healthy range for each growth stage. This calculator gives leaf VPD and air VPD, the dew point, the humidity you need to reach a target, a colour-coded chart for your leaf offset and a log for tracking readings over a day or a crop.
How VPD is calculated
Saturation vapour pressure (SVP) is the most water vapour air can hold at a given temperature. The calculator uses the Tetens equation from FAO Paper 56: SVP = 0.61078 × e^(17.27 T ÷ (T + 237.3)) kPa, with T in °C. Actual vapour pressure of the air is SVP at air temperature × relative humidity ÷ 100. Air VPD is the difference between the two. Leaf VPD replaces the first term with SVP at leaf temperature, because transpiring leaves are usually 1 to 3 °C cooler than the air under normal lights and somewhat warmer under strong lamps without airflow. Measure leaf temperature with an infrared thermometer and type the difference as the leaf offset.
Targets by stage
Young plants and cuttings have small roots and are best kept at a low VPD, about 0.4 to 0.8 kPa, so they lose little water. Vegetative plants are often run between about 0.8 and 1.2 kPa, and flowering and fruiting crops at about 1.2 to 1.5 kPa. Below about 0.4 kPa, leaves struggle to transpire and diseases such as botrytis and powdery mildew spread more easily; above about 1.6 kPa, many plants close their stomata to save water and growth slows. These ranges are common grower targets and vary by crop, so the target fields are editable.
What to change
When VPD is too low, the air is too humid for the temperature: raise the temperature slightly, run a dehumidifier or exchange more air. When it is too high, the air is too dry: lower the temperature or add humidity. The calculator solves for the relative humidity that gives the middle of your target at the current temperature, which is the most direct setting for a humidistat.
The chart and the log
The chart tab colours a grid of temperatures and humidities by zone for your leaf offset, so you can see at a glance which combinations work. The log stores readings with time stamps and plots VPD against the target band, which helps when lights switch off and humidity climbs at night.
Worked example
At 26 °C and 60 % RH with leaves 2 °C cooler, SVP at the leaf (24 °C) is about 2.98 kPa and the air holds about 2.02 kPa, so leaf VPD is about 0.97 kPa: right in the vegetative band. Air VPD at the same reading is about 1.34 kPa, which shows how much the leaf offset matters.
Limits
VPD is one environmental signal, not a complete growing recipe; light, CO₂, root zone and airflow matter as much. The stage ranges are examples, not crop-specific research values. Cheap hygrometers can be off by 5 % RH or more, so calibrate them.
풀이 예시
26 °C, 60 % RH, leaves 2 °C cooler: leaf VPD ≈ 0.97 kPa (vegetative range); air VPD ≈ 1.34 kPa.
한눈에 보기
- 카테고리: 집 및 생활
- 브라우저에서 실행되며 가입도 업로드도 필요 없습니다.
- 입력한 정보는 기기에 머뭅니다.
- 영어로 제공됩니다.
- 콘텐츠 최종 검토일:
- 공식 출처: FAO Irrigation and Drainage Paper 56, chapter 3: saturation vapour pressure and vapour pressure deficit
자주 묻는 질문
What is a good VPD for vegetative growth?
Many growers aim for about 0.8 to 1.2 kPa during vegetative growth, lower for cuttings and seedlings and higher, about 1.2 to 1.5 kPa, in flowering. Check guidance for your crop.
What is the difference between leaf VPD and air VPD?
Air VPD uses the air temperature on both sides of the calculation. Leaf VPD uses the leaf temperature for the saturation term, which is what the plant actually experiences. With cooler leaves, leaf VPD is lower than air VPD.
How do I measure leaf temperature?
Point an infrared thermometer at the top of several healthy leaves under the lights and average the readings, then subtract from the air temperature to get the offset.
What humidity should I set?
The calculator shows the humidity range that gives your target VPD at the current temperature, and the single value for the middle of the range.
Can I use Fahrenheit?
Yes. Switch the units to °F; temperature and leaf offset are converted and every result is shown in Fahrenheit.
Why is low VPD a problem?
At low VPD leaves transpire slowly, nutrient uptake slows and water can condense on leaves, which helps fungal diseases spread.