Room Lighting Calculator (Lux and Lumens)
Choose the room type or enter a lux level, enter room size, lamp lumens and watts, and get lumens needed, number of lamps, energy use and spacing.
브라우저에서 실행됩니다. 파일은 기기 밖으로 나가지 않습니다. 확인하는 방법 보기
…
사용 방법
- 1Choose the room
Or enter lux.
- 2Enter dimensions
Length and width.
- 3Enter lamp data
Lumens and watts.
- 4Adjust factors
UF and MF.
- 5Read lamps
And energy use.
이 도구 소개
Good lighting is measured in lux: lumens of light falling on each square metre. A living room needs around 150 lux for general lighting, a kitchen about 300 lux with 500 on worktops, and an office or study about 500 lux at the desk. Lamps are rated in lumens, and only part of their light reaches the work surface because of fittings, walls and dirt. The lumen method used by lighting designers accounts for this with a utilisation factor and a maintenance factor. This calculator tells you how many lamps to buy, the power they use and how to space them.
Who this is for
Home renovators, electricians, small business owners, office managers and design students.
The lumen method
Lumens needed = target lux × area / (utilisation factor × maintenance factor). The utilisation factor (often 0.4 to 0.6) is the share of light reaching the working plane; light-coloured rooms and efficient fittings score higher. The maintenance factor (about 0.8) allows for dirt and lamp ageing.
Recommended levels
Typical recommendations: living room 150 lux, bedroom 100, bathroom 200, kitchen 300 (500 at worktops), home office 500, classroom 300, office 500, shop floor 300, workshop 500, corridor 100, warehouse 150 and garage 200. Older people need more light for the same tasks.
Lamps and energy
A typical LED gives about 100 lumens per watt; an 800 lumen bulb (similar to an old 60 W bulb) uses about 8 W. The calculator shows total watts and yearly kWh for your daily hours.
Spacing
For an even grid, lamp spacing is about the square root of area per lamp. Keep spacing no more than about 1.5 times the mounting height for uniform light.
A worked example
A 4 × 3.5 m kitchen needs 300 lux. With UF 0.5 and MF 0.8, that is 10,500 lumens: 14 LED lamps of 800 lumens, about 320 lux, using 112 W and about 164 kWh a year at 4 hours a day. Under-cabinet strips can supply the extra light on worktops.
Colour temperature
Warm white (2,700 to 3,000 K) suits living spaces; neutral white (4,000 K) suits kitchens and work areas.
## Layers of light Good rooms combine ambient light for general use, task light where you work or read, and accent light for mood. The lumen method sizes the ambient layer; add task lights for desks and worktops.
Dimming and controls
Dimmers and separate switching let the same room work for cleaning, cooking and relaxing. Check that LED lamps are marked dimmable when used with dimmers.
Cost of running
LEDs use a fraction of the energy of old incandescent bulbs and last many years, so they usually pay for themselves quickly.
## Glare Avoid bare bright lamps in the line of sight.
Limits
A simplified method; professional designs use photometric software. Not a substitute for an electrician's design.
풀이 예시
A 14 m² kitchen at 300 lux needs about 10,500 lumens: 14 lamps of 800 lumens.
한눈에 보기
- 카테고리: 공학 및 건설
- 브라우저에서 실행되며 가입도 업로드도 필요 없습니다.
- 입력한 정보는 기기에 머뭅니다.
- 영어로 제공됩니다.
- 콘텐츠 최종 검토일:
- 공식 출처: Lumen method; recommended illuminance after EN 12464-1 (workplaces) and CIBSE / IES guidance
자주 묻는 질문
How many lux does a kitchen need?
About 300 lux, and 500 on worktops.
How many lumens per square metre?
Lux equals lumens per m² reaching the surface; allow for losses.
What is the utilisation factor?
The share of lamp light that reaches the working surface.
How many lumens does a 60 W equivalent bulb give?
About 800 lumens.
How should lamps be spaced?
Evenly, at about the square root of area per lamp.
Is my data stored?
No. It stays in your browser.