Power Dissipation and Thermal Calculator

Check whether a regulator, diode or chip will overheat, and size a heatsink before the prototype starts smelling hot.

브라우저에서 실행됩니다. 파일은 기기 밖으로 나가지 않습니다. 확인하는 방법 보기

…

사용 방법

  1. 1
    Choose the heat source

    Regulator, diode, logic or power.

  2. 2
    Enter electrical values

    Voltages and currents.

  3. 3
    Read the dissipation

    And efficiency.

  4. 4
    Enter thermal data

    Ambient and θ values.

  5. 5
    Check the junction temperature

    Against the maximum.

  6. 6
    Size a heatsink

    If needed.

이 도구 소개

Heat is the most common cause of electronics failure, and the culprit is often a part that looked fine on the schematic. A linear regulator dropping 12 V to 5 V at half an amp turns more than half its input power into heat. A diode carrying a few amps dissipates watts. Whether that is a problem depends on the part's thermal resistance and the surrounding air temperature. This calculator first works out the power dissipated: for a linear (LDO) regulator from input and output voltages, load current and quiescent current, with the efficiency; for a switching converter from output power and efficiency; for a diode from forward voltage and current or for a MOSFET from its on-resistance; for CMOS logic from switched capacitance, supply voltage, clock frequency and activity factor; or from a power you already know. It then calculates the junction temperature without a heatsink from the junction-to-ambient thermal resistance and the ambient temperature, compares it with the maximum, and if it is too hot, tells you the heatsink thermal resistance needed using the junction-to-case and interface resistances.

The thermal model

Heat flows from the silicon junction to the air through a chain of thermal resistances, each in °C per watt. Without a heatsink: Tj = Ta + P × θJA. With a heatsink: Tj = Ta + P × (θJC + θCS + θSA), where θCS is the thermal interface (pad or paste) and θSA the heatsink itself. The required heatsink is θSA = (Tjmax − Ta) / P − θJC − θCS.

Linear regulators

An LDO dissipates (Vin − Vout) × Iout plus a small quiescent loss. Efficiency is roughly Vout / Vin, so dropping 12 V to 3.3 V wastes about three quarters of the power. When the difference or the current is large, a switching regulator is usually the better choice.

Datasheet numbers

θJA in datasheets is measured on a standard JEDEC test board. On your board it may be much better (thick copper, many vias, a large ground plane under an exposed pad) or worse (small board in a closed box). Use the datasheet's own curves and layout guidance, and measure with a thermocouple or thermal camera.

Margins

Silicon lifetime roughly halves for every 10 °C rise. Design for at least 10 to 20 °C below the maximum junction temperature, and calculate at the highest ambient temperature the product will see, inside its enclosure.

CMOS dynamic power

P = α × C × V² × f shows why lowering the supply voltage saves so much power: halving the voltage cuts dynamic power by three quarters.

Limits

Steady-state only: short pulses heat parts less, and transient thermal impedance curves are needed for them. MOSFET on-resistance rises with temperature, which increases loss; use the hot value. This is an engineering estimate, not a substitute for measurement.

풀이 예시

An LDO dropping 12 V to 5 V at 0.5 A dissipates about 3.56 W at 41% efficiency; with θJA of 50 °C/W at 40 °C ambient the junction would reach 218 °C, so it needs a heatsink of 20 °C/W or better, or a switching regulator.

한눈에 보기

자주 묻는 질문

How hot will my regulator get?

Ambient temperature plus power times θJA.

When do I need a heatsink?

When the calculated junction temperature exceeds the maximum minus a safety margin.

Is an LDO efficient?

Only when input and output voltages are close; efficiency is about Vout/Vin.

What is θJA?

The thermal resistance from junction to surrounding air, in °C per watt.

Does PCB copper help?

Yes. Large copper areas and thermal vias can greatly lower the effective θJA.

Is anything uploaded?

No. Calculations run in your browser.

완전 무료요금 없음, 가입 없음
파일은 비공개로 유지됩니다모든 작업이 브라우저 안에서 이루어집니다
내 언어로 쉽게여러 언어로 제공