Power Dissipation and Thermal Calculator
Check whether a regulator, diode or chip will overheat, and size a heatsink before the prototype starts smelling hot.
브라우저에서 실행됩니다. 파일은 기기 밖으로 나가지 않습니다. 확인하는 방법 보기
…
사용 방법
- 1Choose the heat source
Regulator, diode, logic or power.
- 2Enter electrical values
Voltages and currents.
- 3Read the dissipation
And efficiency.
- 4Enter thermal data
Ambient and θ values.
- 5Check the junction temperature
Against the maximum.
- 6Size a heatsink
If needed.
이 도구 소개
Heat is the most common cause of electronics failure, and the culprit is often a part that looked fine on the schematic. A linear regulator dropping 12 V to 5 V at half an amp turns more than half its input power into heat. A diode carrying a few amps dissipates watts. Whether that is a problem depends on the part's thermal resistance and the surrounding air temperature. This calculator first works out the power dissipated: for a linear (LDO) regulator from input and output voltages, load current and quiescent current, with the efficiency; for a switching converter from output power and efficiency; for a diode from forward voltage and current or for a MOSFET from its on-resistance; for CMOS logic from switched capacitance, supply voltage, clock frequency and activity factor; or from a power you already know. It then calculates the junction temperature without a heatsink from the junction-to-ambient thermal resistance and the ambient temperature, compares it with the maximum, and if it is too hot, tells you the heatsink thermal resistance needed using the junction-to-case and interface resistances.
The thermal model
Heat flows from the silicon junction to the air through a chain of thermal resistances, each in °C per watt. Without a heatsink: Tj = Ta + P × θJA. With a heatsink: Tj = Ta + P × (θJC + θCS + θSA), where θCS is the thermal interface (pad or paste) and θSA the heatsink itself. The required heatsink is θSA = (Tjmax − Ta) / P − θJC − θCS.
Linear regulators
An LDO dissipates (Vin − Vout) × Iout plus a small quiescent loss. Efficiency is roughly Vout / Vin, so dropping 12 V to 3.3 V wastes about three quarters of the power. When the difference or the current is large, a switching regulator is usually the better choice.
Datasheet numbers
θJA in datasheets is measured on a standard JEDEC test board. On your board it may be much better (thick copper, many vias, a large ground plane under an exposed pad) or worse (small board in a closed box). Use the datasheet's own curves and layout guidance, and measure with a thermocouple or thermal camera.
Margins
Silicon lifetime roughly halves for every 10 °C rise. Design for at least 10 to 20 °C below the maximum junction temperature, and calculate at the highest ambient temperature the product will see, inside its enclosure.
CMOS dynamic power
P = α × C × V² × f shows why lowering the supply voltage saves so much power: halving the voltage cuts dynamic power by three quarters.
Limits
Steady-state only: short pulses heat parts less, and transient thermal impedance curves are needed for them. MOSFET on-resistance rises with temperature, which increases loss; use the hot value. This is an engineering estimate, not a substitute for measurement.
풀이 예시
An LDO dropping 12 V to 5 V at 0.5 A dissipates about 3.56 W at 41% efficiency; with θJA of 50 °C/W at 40 °C ambient the junction would reach 218 °C, so it needs a heatsink of 20 °C/W or better, or a switching regulator.
한눈에 보기
- 카테고리: 공학 및 건설
- 브라우저에서 실행되며 가입도 업로드도 필요 없습니다.
- 입력한 정보는 기기에 머뭅니다.
- 영어로 제공됩니다.
- 콘텐츠 최종 검토일:
- 공식 출처: Texas Instruments: Semiconductor and IC Package Thermal Metrics (SPRA953)
자주 묻는 질문
How hot will my regulator get?
Ambient temperature plus power times θJA.
When do I need a heatsink?
When the calculated junction temperature exceeds the maximum minus a safety margin.
Is an LDO efficient?
Only when input and output voltages are close; efficiency is about Vout/Vin.
What is θJA?
The thermal resistance from junction to surrounding air, in °C per watt.
Does PCB copper help?
Yes. Large copper areas and thermal vias can greatly lower the effective θJA.
Is anything uploaded?
No. Calculations run in your browser.