Gel Band Densitometry Analyzer
Open a gel or blot photo, detect lanes automatically or click to add them, subtract the background, find and integrate bands, compare them with a reference band, size them against a ladder and export a results CSV and an annotated image.
브라우저에서 실행됩니다. 파일은 기기 밖으로 나가지 않습니다. 확인하는 방법 보기
…
사용 방법
- 1Open the image
Gel or blot photo.
- 2Set lanes
Auto-detect or click.
- 3Tune detection
Background and prominence.
- 4Size and compare
Ladder and reference.
- 5Export
CSV and annotated PNG.
이 도구 소개
Densitometry turns the bands on a gel or western blot into numbers, so you can compare expression levels, check loading or estimate DNA concentration against a standard. The classic route is to draw lanes in an image program, plot profiles and integrate peaks by hand. This analyzer automates the routine in your browser. Open a photo of a DNA gel, protein gel or blot. Lanes are detected from the image or added by clicking. For each lane the tool draws the intensity profile from top to bottom, estimates the background with a rolling-ball style filter, finds the bands and integrates the area of each band above the background.
Who this is for
Students quantifying a western blot for a lab report, researchers checking PCR yields or loading, and teaching labs where image analysis software is not installed.
Images
Use the original, unprocessed image from the imager, ideally a TIFF or PNG exported without auto-contrast. For gels with light bands on a dark background leave the default. For Coomassie gels and western blots with dark bands on a light background, tick the inversion option so bands count as signal.
Lanes
Auto-detect finds lane centres from the column profile. You can set the lane width, the top and bottom of the area analysed, nudge any lane centre or remove a lane, and switch on click to add lanes by clicking on the image. Lanes are numbered from left to right on the overlay.
Background and bands
The background radius controls the rolling-ball style opening used to estimate the background under the bands: it should be larger than the width of a band. The minimum prominence sets how strong a peak must be, as a percentage of the strongest band in the lane, to count as a band. Smoothing reduces pixel noise.
Profiles
The lane profile plot shows the raw profile in black, the background as a red dashed line and each integrated band area in blue, so you can see exactly what is being measured.
Sizing
Choose the ladder lane and list its band sizes from top to bottom. Other bands are sized by semi-log interpolation between neighbouring ladder bands, the usual approach for agarose and SDS-PAGE gels.
Quantities
Each band shows its area, its percentage of the lane total and its ratio to a reference band you choose, such as a loading control or a standard. Download the results and lane profiles as CSV and the annotated image as PNG.
Tips
- Avoid saturated bands; reduce exposure if bands are pure white or black. - Normalise western blot targets to a loading control from the same lane.
Limits
Densitometry is semi-quantitative and depends on the linear range of the stain and camera. This is not a substitute for validated analysis software in regulated work.
풀이 예시
On the sample gel, auto-detect finds six lanes and the ladder lane shows 12 bands from 10,000 to 250 bp. The sample bands are sized at 1,199 and 3,488 bp, and the lower band's area rises from 349 in lane 2 to 1,373 in lane 6, about 3.9 times more.
한눈에 보기
- 카테고리: 수학 및 과학
- 브라우저에서 실행되며 가입도 업로드도 필요 없습니다.
- 입력한 정보는 기기에 머뭅니다.
- 영어로 제공됩니다.
- 콘텐츠 최종 검토일:
- 공식 출처: NIH ImageJ user guide: gel analysis (lane profiles and band integration)
자주 묻는 질문
Which images can I use?
Photos or scans of DNA gels, protein gels and western blots in common image formats.
How is background removed?
With a rolling-ball style morphological filter on each lane profile.
Can it size bands?
Yes, by semi-log interpolation against a ladder lane.
Can I compare bands to a loading control?
Yes. Choose a reference band and every band gets a ratio.
Dark bands on a light background?
Tick the inversion option for Coomassie gels and blots.
Is my image uploaded?
No. Analysis runs in your browser.