Drain Pipe Slope and Fall Calculator
Convert between 1:40, inches per foot, percent and mm per metre, then build a drain run of segments with bends, chambers and backdrops. The tool gives the invert level and depth at every node, draws the long section with the ground line and checks the pipe's flow capacity and self-cleansing velocity.
ブラウザ内で動作します。ファイルは端末の外に出ません。 確認方法を見る
…
使い方
- 1Convert the gradient
On the quick tab type the length and gradient in any form to get the fall and the other forms.
- 2Set the start level
On the run tab type the starting invert level and the ground level at the start.
- 3Add segments
Add each pipe length with its gradient, the fitting at its end, any backdrop and the ground level.
- 4Check the levels
Read invert levels, depths and the total fall in the table and on the long section drawing.
- 5Check the flow
On the flow tab choose the pipe, material and design flow and read the depth and velocity.
- 6Print the sheet
Print the level sheet or export the table as CSV for setting out on site.
このツールについて
Every gravity drain needs enough fall to carry water and solids away, but not so much depth that the far end ends up below the sewer connection. Builders and plumbers describe the slope in different ways: 1 in 40 in the UK and Australia, a quarter inch per foot in the US, percent on civil drawings, millimetres per metre on site. This calculator converts between all four and turns them into levels. The quick tab answers the everyday question: over this length at this gradient, how much does the pipe drop, or what gradient do I have if I know the fall. The main tab handles a whole run. Enter the starting invert level, which is the level of the inside bottom of the pipe, and add segments, each with its length, gradient and the fitting at its end, such as a bend, an inspection chamber or a junction. A backdrop at a chamber lowers the invert without changing the gradient. The tool lists the chainage, invert level, ground level and depth to invert at every node, so you can set out the trench with a laser or a level and check the cover at each point before you dig.
Long section and flow
The long section drawing shows the pipe invert and soffit against chainage with the ground line above it, the levels written at each node, and backdrops as vertical steps. You can print the level sheet or export it as CSV. The flow tab uses Manning's equation for a circular pipe to give the full-bore and half-full capacity at the flattest gradient of the run, the depth at your design flow and the velocity at that depth. Drains should reach a self-cleansing velocity, often taken as about 0.75 m/s, at least once a day; a steeper gradient helps more than a larger pipe.
Codes and example values
Minimum gradients differ. UK Approved Document H accepts 1:40 for small branch drains and flatter falls for 100 mm pipes that serve a WC; US plumbing codes ask for a quarter inch per foot on small pipes and an eighth on larger ones. The presets in the tool are example figures for orientation; the code adopted where you build, and the building control officer or plumbing inspector, decide. Manning n values for plastic, clay, concrete and cast iron are typical published figures for clean pipes.
Limits
This is not a sewer network design tool. It does not size pipes from fixture units or discharge units, does not handle pumped or vacuum drainage and does not check ventilation, trap seals or the structural cover needed under roads.
計算例
A kitchen drain leaves the house at invert level 99.400 m. The first 6 m to a long radius bend falls at 1:40, giving 0.150 m of fall and an invert of 99.250 m. The next 8.5 m to an inspection chamber also falls at 1:40, ending at 99.0375 m. The last 12 m to the sewer junction falls at 1:60, plus a 0.30 m backdrop, so the outlet invert is 98.5375 m and the total fall is 0.8625 m over 26.5 m. A 100 mm PVC pipe at 1:60 carries 9.6 L/s full; at a design flow of 1.5 L/s it runs 27 percent full at 0.89 m/s, above the self-cleansing target.
ポイント
- カテゴリ: 工学・建設
- ブラウザ内で動作し、登録もアップロードも不要です。
- 入力した情報は端末内にとどまります。
- 英語で利用できます。
- 内容の最終確認日:
- 公式情報源: Manning equation for gravity flow in circular pipes; UK Approved Document H and US IPC minimum gradients (example presets)
よくある質問
What is a 1:40 gradient?
The pipe drops 1 unit for every 40 units of length: 25 mm per metre, 2.5 percent or about 0.3 inch per foot. Over 10 m the fall is 250 mm.
How do I convert 1/4 inch per foot to a ratio?
A foot is 12 inches, so a quarter inch per foot is 1 in 48, which is about 2.08 percent or 20.8 mm per metre. Type it in the quick tab to see every form.
What is an invert level?
It is the level of the lowest inside point of the pipe. Setting out uses invert levels because the flow runs along the invert; the top of the pipe, the soffit, is one inside diameter higher.
Can a drain be too steep?
Very steep runs can let water outrun solids. Many guides prefer gradients flatter than about 1:20 for long runs and use a backdrop or a ramp at a chamber to drop height instead.
Why does the tool use the flattest segment for capacity?
The flattest part of a run of one pipe size has the least capacity and the lowest velocity, so it controls whether the drain copes with the design flow.
Does the long section show cover depth?
Yes, when you type ground levels at the start and at each node, the table shows the depth from ground to invert and the drawing shows the ground line, so you can check the minimum cover.