Intraclass Correlation (ICC) Calculator

Type or paste a subjects-by-raters table, answer three questions about your design, and get the right ICC with its confidence interval, plus all six forms, the ANOVA working and a ratings plot.

Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo

…

Come si usa

  1. 1
    Enter ratings

    Type into the grid, paste a wide or long table, import a CSV or load a sample.

  2. 2
    Describe the design

    Answer who rated, whether agreement or consistency matters, and single or mean use.

  3. 3
    Read the chosen ICC

    See the value, its confidence interval, the F test and the band.

  4. 4
    Compare all forms

    Open the table of six forms to see how the choice changes the result.

  5. 5
    Check the working

    Look at the ANOVA table, the rater means and each formula with your numbers.

  6. 6
    Report

    Copy the result sentence, download the CSV or print the report.

Informazioni su questo strumento

The intraclass correlation coefficient measures how much of the variation in a set of measurements comes from real differences between the things being measured rather than from the people or instruments doing the measuring. It is the standard statistic for inter-rater and test-retest reliability in medicine, physiotherapy, psychology and education. Unlike Pearson's correlation, the ICC can penalise a rater who scores everyone two points higher, and it works with three, four or more raters at once. The catch is that there are six common forms, and choosing the wrong one is the most frequent error in published reliability studies. This calculator asks three plain questions: whether each subject was rated by the same raters, whether those raters are a sample or the only ones you care about, and whether you need absolute agreement or just the same ranking. It then highlights the matching form with both naming systems, Shrout-Fleiss ICC(2,1) and McGraw-Wong ICC(A,1), so you can match it to SPSS or R output. Ratings go into an editable grid where you can add and remove subjects and raters, or you can paste a wide or long table. The two-way ANOVA table, the formula for every form with your mean squares filled in, and a dot plot of each subject's ratings are a click away.

Choosing between the forms

Use the one-way model, ICC(1), when each subject was scored by a different set of raters, for example when patients were seen by whichever clinician was on duty. When the same raters scored every subject, use the two-way models. If the raters are a random sample and the result should apply to other raters like them, choose two-way random effects, ICC(2). If these raters are the only ones that matter, choose two-way mixed, ICC(3). Absolute agreement asks whether the scores match; consistency only asks whether the raters rank the subjects the same way. Finally, pick single measures if in practice one rater will score each subject, or average measures if you will use the mean of k raters.

Worked example

The first sample is the classic table from Shrout and Fleiss: six targets each scored by four judges. The ANOVA gives mean squares of 11.242 between targets, 32.486 between judges, 1.019 for the residual and 6.264 within targets. ICC(1,1) = 0.166 with a 95% interval from −0.133 to 0.723. ICC(2,1) = 0.290 (0.019 to 0.761), and ICC(3,1) = 0.715 (0.342 to 0.946). The average-measure forms are 0.443, 0.620 and 0.909. The large gap between ICC(2,1) and ICC(3,1) shows that the judges rank the targets similarly but differ a lot in how severely they score: judge 1 averages 7.67 while judge 2 averages 2.50. These figures match the values in the original paper and the output of R's psych package.

Limits

The ICC depends on how varied the subjects are, so a sample of very similar subjects gives a low ICC even with careful raters. Rows with a missing rating are left out rather than imputed. The tool does not fit multilevel models for unbalanced designs, and it does not replace kappa for categorical ratings.

Esempio svolto

Shrout-Fleiss data, 6 targets and 4 judges: ICC(2,1) = 0.29 (95% CI 0.02 to 0.76), ICC(3,1) = 0.71, ICC(3,k) = 0.91.

In breve

Domande frequenti

What is a good ICC value?

Koo and Li suggest below 0.5 poor, 0.5 to 0.75 moderate, 0.75 to 0.9 good and above 0.9 excellent. Read the band from the confidence interval: an ICC of 0.8 with an interval from 0.5 to 0.93 could be anything from moderate to excellent.

Why can the ICC be negative?

A negative estimate means the variation within subjects is larger than the variation between them. The true ICC cannot be below zero, so treat it as zero reliability, usually caused by too few or too similar subjects.

How do Shrout-Fleiss and McGraw-Wong names match?

ICC(1,1) is ICC(1), ICC(2,1) is ICC(A,1), and ICC(3,1) is ICC(C,1). The k versions are the average-measure forms. SPSS uses the McGraw-Wong labels with model and type options.

What data layout does the calculator accept?

Wide: one row per subject with a column per rater, optionally with labels and a header. Long: three columns for subject, rater and score. Paste either, or import a CSV.

How many subjects and raters do I need?

At least two of each to compute anything, but Koo and Li recommend at least 30 subjects and 3 raters for a reliability study. With few subjects the interval is very wide.

Should I use single or average measures?

Choose by how the measurement will be used later. If one clinician will measure each patient, report the single-measure ICC. If the score will be the mean of several raters, report the average-measure form.

Completamente gratisNessun costo, nessuna registrazione
I file restano privatiTutto funziona nel tuo browser
Facile nella tua linguaDisponibile in molte lingue