Flow Cytometry FCS File Viewer
Open .fcs files from BD, Beckman Coulter, Cytek, Sony and other cytometers, plot any two channels as a density scatter or one as a histogram on linear, log or arcsinh axes, draw polygon, rectangle and range gates in a hierarchy, read counts and percentages, apply the file's compensation and export events or statistics to CSV.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1Open the file
Drop an .fcs file from your cytometer.
- 2Plot channels
Pick X and Y channels or Histogram, and choose linear, log or arcsinh scales.
- 3Gate
Draw a polygon, rectangle or range gate; it becomes population P1, P2 and so on.
- 4Build a hierarchy
In a new plot choose the population to show and gate inside it.
- 5Read the numbers
Check counts, percentages and medians in the Populations table.
- 6Export
Save events or statistics as CSV, the gate set as JSON or plots as PNG.
Informazioni su questo strumento
Every flow cytometer saves its results as FCS files, a format kept by the International Society for Advancement of Cytometry. A file holds a header with byte offsets, a text segment of keywords such as $PAR (number of parameters), $TOT (number of events), $PnN channel names and $PnS stain labels, and the data segment with one value per channel for every cell. Analysis software can be expensive, and sometimes you just need to see what is in a file, check a gate or pull counts for a report. This viewer reads FCS 2.0, 3.0 and 3.1 list-mode files in the browser, including integer data with log amplification and float or double data in either byte order. It starts with a forward scatter against side scatter plot and lets you add as many plots as you like. Points are binned into a 256 by 256 grid and coloured by density on a log scale, so even a million events draw quickly. Choose linear, log or arcsinh scales; the arcsinh cofactor, 150 by default, can be changed for spectral or mass data. Draw a polygon by tapping corners, a rectangle by dragging, or a range on a histogram. Each gate becomes a population that other plots can show, so you can gate lymphocytes, then single cells, then CD4 positive cells.
Populations
The table lists every gate with its parent, the number of events, the percentage of the parent and of all events, and the median of a channel you pick. Gates can be renamed or deleted (child gates go with them), saved as a JSON gate set and loaded again for the next file from the same panel.
Compensation
If the file carries a $SPILLOVER or SPILL matrix, as files from most modern instruments do, the Compensate box applies its inverse to the named channels. Turning it off shows the raw values. Matrices from separate compensation controls are not calculated here.
Exports
Events of any population as CSV with every channel, population statistics as CSV, gate sets as JSON and PNG of each plot.
Limits
This is a viewer for research data, not a clinical diagnostic system, and results are not validated for patient care. Automated clustering, tSNE or UMAP, batch analysis of many files, logicle and hyperlog transforms and Gating-ML import are not included; ASCII-type data files are not read.
Esempio svolto
A student opens a PBMC sample stained with CD3 FITC and CD4 PE: 50,000 events, 6 parameters and a 2 by 2 spillover matrix. On FSC-A against SSC-A he draws a polygon around lymphocytes (P1, 31,420 events, 62.8 percent). A second plot of CD3 FITC-A against CD4 PE-A on arcsinh axes shows population P1; a rectangle gate on CD3 and CD4 positive cells gives P2 with 12,880 events, 41.0 percent of P1 and 25.8 percent of all events. He exports the population statistics CSV and the P2 events for a figure in R.
In breve
- Categoria: Matematica e scienze
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: ISAC Data File Standard for Flow Cytometry, FCS 3.1 (Spidlen et al., 2010)
Domande frequenti
Which instruments are supported?
Any instrument that writes standard FCS 2.0, 3.0 or 3.1 list-mode files, including BD FACSCanto, LSRFortessa and Accuri, Beckman Coulter CytoFLEX, Cytek Aurora, Sony and Thermo Attune. Vendor project files such as .wsp workspaces are not FCS and are not read.
Why do my fluorescence plots look squeezed on a linear axis?
Fluorescence spans several decades. Switch the axis to arcsinh, which spreads low values and still shows negative values after compensation, or to log for older log-amplified data.
What does the arcsinh cofactor do?
It sets where the scale changes from nearly linear to nearly logarithmic. Around 150 suits conventional fluorescence data; spectral cytometers often use 1,000 or more and mass cytometry 5.
Can I reuse my gates on another file?
Yes. Save gates writes a JSON file with the gates and plots. Open the next file from the same panel and load it; gates refer to channels by position, so the channel order must be the same.
Is the compensation the same as in my analysis software?
It uses the matrix stored in the file. If you recalculated compensation in other software and did not write it back, the values will differ.
Are files uploaded?
No. FCS files are read in your browser and stay on your computer.
