FASTQ Quality Report Viewer
Drop a FASTQ or gzipped FASTQ file and get a quality report in the style of FastQC: per-base and per-read quality, GC and length histograms, base and N content, adapter content, duplication and over-represented sequences, with pass, warn or fail flags.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1Open
Drop a FASTQ or FASTQ.gz file.
- 2Limit
Set the number of reads to analyse.
- 3Flags
Read the pass, warn and fail summary.
- 4Explore
Step through quality, GC, content and adapters.
- 5Save
Download the HTML report or the CSV.
Informazioni su questo strumento
The FASTQ Quality Report Viewer gives a first look at a sequencing run without installing anything. It reads plain FASTQ and gzipped FASTQ, spotting gzip from the first two bytes rather than the file name, and works through the file in 1 MB chunks so the page stays responsive while a progress figure counts up. The reads never leave your computer. Each record is the usual four lines: a header starting with @, the sequence, a plus line and the quality string. If a header line does not start with @, a warning is shown, because the file may not be FASTQ. A box sets how many reads to analyse, 500,000 by default and never fewer than 1,000; when the limit is reached the report says so and describes only those reads. The quality encoding is found from the lowest and highest quality characters. If the lowest character is below ";" the file is Phred+33, the Sanger and Illumina 1.8+ scale. If the lowest is "@" or higher and the highest is above "J", it is treated as Phred+64, the old Illumina 1.3 to 1.7 scale. All scores are shown on the Phred scale either way. The report then builds the modules. The summary shows reads, bases, read length range, encoding, mean GC and the share of duplicate reads. Per-base quality plots the mean, median, lower quartile and 10th percentile at each position against Q20 and Q28 lines, and a second chart counts reads by mean quality. GC content per read is drawn as a histogram with the mean marked, beside the read length chart. Base content shows A, C, G, T and N at each position. Adapter content is cumulative: once one of six 12-base sequences is found in a read, that read counts from that position to the end.
The checks and flags
The six sequences are Illumina Universal (AGATCGGAAGAG), Illumina Small RNA 3' and 5', Nextera Transposase, PolyA and PolyG, matched exactly. Duplication is judged from the first 50 bases of the first 200,000 reads. Over-represented sequences are those first-50-base keys making up 0.1% or more of the sampled reads and seen more than once, up to 20, each with a possible source if it contains the first ten bases of a listed adapter.
Five flags sum it up. Per-base quality fails if any position has a lower quartile under Q10 and warns if any median is under Q20. Adapter content fails above 10% at the last position and warns above 5%. N content fails above 20% at any position and warns above 5%. Duplication fails above 50% and warns above 20%. Over-represented sequences fail if one is above 1% and warn if any are listed.
The sample results
A test file of 100 reads, each 50 bases, shows how the flags behave. The first 40 bases are Q40 and the last ten Q2, so the report shows 5,000 bases, Phred+33 encoding and a per-base fail for 10 positions with a lower quartile under Q10. Ten reads carry the Illumina Universal adapter from base 11, so adapter content reaches 10.0% by the last position, a warning. Every read is padded with C, so mean GC is 70.2%. With only two distinct sequences, duplication is 98.0% and both sequences are over-represented, at 90% and 10%, the second tagged Illumina Universal.
Reports and downloads
HTML report saves the summary, the flags table, every chart and the over-represented list in one file you can open offline. Print / PDF sends the same report to the printer, and Per-base CSV gives position, mean, median, quartiles and the 10th and 90th percentiles for a spreadsheet. The read limit and file name can be kept as a saved project; the reads themselves are never stored.
Who this is for
Bioinformatics students learning what a quality report shows, lab staff checking a run before passing it on, and researchers who need a quick look on a computer without FastQC or Java.
Limits
The position-by-position modules cover the first 500 bases of each read, so long reads are only partly described, and GC per read is taken from those bases too. Adapters are found by exact match only. The Phred+64 guess can be wrong for a very high-quality Phred+33 file whose lowest score is Q31 or more and highest above Q41, so check the encoding line. Paired files are opened one at a time. The flag rules are simple fixed thresholds in the spirit of FastQC, not a copy of it, and a fail in one module can be normal for some library types. The flags are a screen, not advice on whether to re-sequence or how to trim; check the run with your core facility's tools.
Esempio svolto
100 reads of 50 bp (bases 41-50 at Q2, 10 reads with Illumina Universal from base 11): per-base FAIL (10 positions with lower quartile under Q10), adapter WARN 10.0%, mean GC 70.2%, duplication 98.0%.
In breve
- Categoria: Matematica e scienze
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: FASTQ format (Cock et al., Nucleic Acids Research 2010); FastQC module descriptions (Babraham Bioinformatics)
Domande frequenti
Does it accept gzipped files?
Yes. A file whose first two bytes are the gzip signature is decompressed as it is read, whatever its name. Plain .fastq, .fq and .txt files work too.
How is Phred+33 told apart from Phred+64?
From the lowest and highest quality characters. A lowest character below ";" means Phred+33. A lowest of "@" or more with a highest above "J" is treated as Phred+64, the old Illumina 1.3 to 1.7 scale.
Which adapters does it look for?
Illumina Universal, Illumina Small RNA 3' and 5', Nextera Transposase, PolyA and PolyG, each as a 12-base sequence matched exactly. A read counts from the position where the match starts.
How large a file can I open?
The file is read in chunks, but the gzip or text file still has to be loaded by the browser. The read limit, 500,000 by default, keeps the analysis bounded; the report says when it stopped early.
How is duplication measured?
From the first 50 bases of the first 200,000 reads. Reads with the same first 50 bases count as duplicates, which is a quick estimate rather than a full comparison.
Can I keep the report?
Yes. HTML report saves one self-contained file with the tables and charts, Print / PDF prints it, and Per-base CSV saves the per-position quality figures.
