Spectrum Viewer for IR, UV-Vis and NMR
Open JCAMP-DX files, including compressed ones, or two-column CSV, overlay several spectra with offsets, convert transmittance to absorbance, smooth with Savitzky–Golay, subtract a polynomial baseline, normalise, pick peaks and export the figure, peak table and data.
Läuft in Ihrem Browser. Ihre Dateien verlassen nie Ihr Gerät. So prüfen Sie es
…
So geht's
- 1Open spectra
JCAMP-DX or CSV.
- 2Overlay
Colours and offsets.
- 3Process
Smooth, baseline, convert.
- 4Pick peaks
Height and prominence.
- 5Export
Figure, data, peaks.
Über dieses Tool
Spectrometers save data in their own formats, but almost all of them can export JCAMP-DX, the IUPAC standard for exchanging spectra, or plain CSV. Opening those files usually means the instrument software, which lives on one computer in the lab. This viewer opens them in any browser. JCAMP-DX files are decoded fully, including the compressed ASDF forms with squeezed, difference and duplicate characters that many instruments and databases use, as well as XY point lists and peak tables. Several spectra can be overlaid in different colours and offset vertically to compare samples, batches or a product with its starting material.
Who this is for
Chemistry students writing up IR and UV-Vis practicals, researchers comparing spectra away from the instrument, teachers preparing figures and anyone who downloads spectra from public databases.
Axes
IR spectra in wavenumbers and NMR spectra in ppm are drawn with the x axis running from high to low, as is conventional, and other spectra from low to high. You can override the direction and zoom to any x range. Axis titles are set from the units in the file.
Processing
Convert percent transmittance to absorbance or back. Smooth noisy spectra with a Savitzky–Golay filter, which keeps peak positions and heights better than a moving average. Subtract a polynomial baseline fitted iteratively below the spectrum, and normalise to a maximum of one to compare shapes.
Peak picking
Peaks are found by height and prominence, as percentages of the spectrum's range. For transmittance spectra the tool looks for minima, since absorption bands point down. Peak positions are labelled on the plot and listed in a table you can download.
Export
Download the figure as SVG or a high-resolution PNG, the processed data as CSV or JCAMP-DX, and the peak table as CSV.
Tips
- Compare spectra recorded with the same resolution and path length. - Smooth gently: too much smoothing broadens and merges peaks. - Use the baseline correction before comparing peak heights.
Common mistakes
- Reading peak positions from a transmittance spectrum as maxima. - Overlaying spectra in different units without converting.
Reading IR spectra
The region from 4000 to 1500 cm⁻¹ holds the functional group bands, such as the broad O–H stretch near 3300, C–H stretches just below 3000 and the strong C=O stretch near 1700. Below 1500 cm⁻¹ is the fingerprint region, best used to compare a sample with a reference spectrum of the same compound.
Reading UV-Vis spectra
For UV-Vis, the wavelength of maximum absorbance and the absorbance there are the key values. Within the linear range, absorbance is proportional to concentration, so a baseline-corrected peak height can be used with a calibration curve.
Limits
Two-dimensional NMR and raw FID data are not supported, and peak positions are the highest or lowest recorded point without interpolation. This is not a substitute for expert spectroscopic advice.
Rechenbeispiel
The compressed sample JCAMP file decodes to 21 points from 400 to 440 nm, with a peak absorbance of 0.495 at 420 nm, while the synthetic IR sample shows its strongest bands at 3340 and 1048 cm⁻¹ when picked as minima.
Kurzinfos
- Kategorie: Mathe & Wissenschaft
- Läuft in Ihrem Browser, ohne Anmeldung, ohne Upload.
- Ihre Eingaben bleiben auf Ihrem Gerät.
- Auf Englisch verfügbar.
- Inhalt zuletzt geprüft:
- Offizielle Quelle: IUPAC JCAMP-DX standard for spectroscopic data exchange (McDonald and Wilks, 1988)
Häufig gestellte Fragen
Which file formats are supported?
JCAMP-DX (AFFN and compressed ASDF), and two-column CSV or text.
Can I overlay spectra?
Yes, with colours, vertical offsets and a legend.
Can it convert transmittance to absorbance?
Yes, in either direction.
How does baseline correction work?
A polynomial is fitted iteratively below the spectrum and subtracted.
Does it pick peaks?
Yes, maxima or minima with height and prominence thresholds.
Is my data uploaded?
No. Files are read in your browser.