Humidity and Dew Point Calculator

Enter the air temperature and one humidity measurement (relative humidity, dew point or wet-bulb temperature) to get every other humidity value at once.

Läuft in Ihrem Browser. Ihre Dateien verlassen nie Ihr Gerät. So prüfen Sie es

…

So geht's

  1. 1
    Enter the temperature

    Air temperature in °C.

  2. 2
    Choose your measurement

    Relative humidity, dew point or wet bulb.

  3. 3
    Enter the value

    Percentage or temperature.

  4. 4
    Enter pressure

    Station pressure in hPa.

  5. 5
    Read the results

    Dew point, RH, wet bulb, absolute humidity and more.

Über dieses Tool

Humidity can be described in many ways, and each one answers a different question. Relative humidity tells you how close the air is to saturation, the dew point tells you the temperature at which condensation starts, absolute humidity gives the mass of water vapour in a cubic metre of air, and the mixing ratio is what meteorologists use to follow air as it rises. This calculator converts between all of them from a single measurement, using the saturation vapour pressure formula recommended in the meteorological literature, and shows how much other common formulas differ.

Who this is for

Students of meteorology and physics, weather observers, HVAC technicians, greenhouse growers, museum conservators, painters checking coating conditions and anyone with a thermometer and a hygrometer.

Three ways to start

- **Relative humidity**: the reading of most electronic hygrometers. - **Dew point**: given in weather reports and aviation METARs. - **Wet-bulb temperature**: from a sling or aspirated psychrometer. The calculator solves the WMO psychrometer equation, which includes air pressure, so enter the station pressure for the best result.

The formulas

Saturation vapour pressure over water uses the Magnus form with the coefficients of Alduchov and Eskridge (1996): es = 6.1094 · exp(17.625 T / (T + 243.04)) hPa. It is accurate to about 0.3 % between −40 and +50 °C. The vapour pressure e is RH × es, the dew point inverts the same formula, and below 0 °C the frost point uses the ice coefficients.

Absolute humidity is 216.7 × e / T(K) in g/m³. The mixing ratio is 622 e / (p − e) g/kg and specific humidity 622 e / (p − 0.378 e) g/kg. The wet-bulb temperature is solved iteratively from the psychrometer equation and compared with the Stull (2011) formula, which is valid at sea-level pressure for RH between 5 and 99 %.

Formula comparison

The table compares four saturation vapour pressure formulas at your temperature. They agree within a few tenths of a percent above freezing; over ice the difference becomes larger, which matters for frost and cloud physics.

Comfort guide

Dew point describes how humid the air feels better than relative humidity, because it does not change with temperature. Below 10 °C feels dry, 10 to 16 °C comfortable, 16 to 18 °C slightly humid, 18 to 21 °C humid, 21 to 24 °C very humid and above 24 °C oppressive.

Practical uses

- Condensation risk: a surface colder than the dew point will get wet; painting or concrete pouring is usually avoided within 3 °C of the dew point. - Cloud base: the spread between temperature and dew point gives the height of convective clouds. - Indoor climate: relative humidity between 40 and 60 % limits mould and dust mites.

Good practice

Measure temperature and humidity at the same spot, away from sunlight and walls. Psychrometer readings need good ventilation (at least 3 m/s) and a clean wick. Enter the station pressure, not the sea-level pressure, when you are at altitude.

Worked example

At 25 °C and 50 % relative humidity at sea level, the saturation vapour pressure is 31.6 hPa and the vapour pressure 15.8 hPa. The dew point is 13.9 °C, the wet-bulb temperature 18.0 °C, absolute humidity 11.5 g/m³ and the mixing ratio 9.9 g/kg.

Limits

Formulas assume a flat water surface and ideal-gas behaviour; results above 50 °C or below −40 °C are less accurate. Not a calibration standard.

Rechenbeispiel

At 25 °C and 50 % RH the dew point is 13.9 °C and absolute humidity 11.5 g/m³.

Kurzinfos

Häufig gestellte Fragen

How do I calculate dew point from temperature and humidity?

Find the vapour pressure as RH × saturation vapour pressure, then invert the Magnus formula; the calculator does both steps.

What is the difference between dew point and relative humidity?

Relative humidity depends on temperature; the dew point measures the actual moisture content.

Why does pressure matter?

It affects the mixing ratio and the psychrometer equation, not the dew point from RH.

Which saturation formula is most accurate?

Magnus with Alduchov-Eskridge coefficients and Buck agree within 0.1–0.3 % with reference tables.

What is a comfortable dew point?

Between about 10 and 16 °C for most people.

Is my data stored?

No. Everything is calculated in your browser.

Völlig kostenlosKeine Kosten, keine Anmeldung
Dateien bleiben privatAlles läuft in Ihrem Browser
Einfach in Ihrer SpracheIn vielen Sprachen verfügbar