Solar Panel Temperature Derating and Yield Calculator
Find how much power a solar panel really delivers on a hot day from its temperature coefficient and NOCT, estimate daily and yearly energy from peak sun hours and losses, or work out how many modules can go in a string for your inverter's voltage window.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1Choose temperature, yield or string
Mode.
- 2Enter datasheet values
Pstc, γ, NOCT, Voc, Vmp.
- 3Enter site conditions
Air temperature, irradiance, PSH.
- 4Enter losses
Soiling, wiring, inverter.
- 5Read power, energy and string limits
W, kWh, modules.
Informazioni su questo strumento
Solar panels are rated at standard test conditions: 1,000 W/m² of sunlight and a cell temperature of 25 °C. On a real roof, cells run 20-35 °C hotter than the air, and crystalline silicon loses about 0.3-0.45 % of its power for every degree. Sunlight varies through the day and season, and wiring, dirt and the inverter take their share. This calculator estimates real module power from the datasheet's temperature coefficient and NOCT, the annual energy of a system from peak sun hours and a performance ratio, and the number of modules a string can have without exceeding the inverter's maximum voltage on a cold morning or dropping below its MPPT range on a hot afternoon.
Who this is for
Solar installers and designers, homeowners comparing quotes, energy consultants and engineering students.
Cell temperature and power
- Tc = Ta + (NOCT − 20) / 800 × G. With NOCT 45 °C, 30 °C air and 800 W/m², cells reach about 55 °C. - P = Pstc × (1 + γ × (Tc − 25)) × G / 1,000, with γ the power temperature coefficient (about −0.35 %/°C for modern mono PERC and TOPCon, −0.26 to −0.30 %/°C for heterojunction). A 400 W module then gives about 286 W: 20 % less light and a further 10.5 % temperature loss.
Peak sun hours and yield
Peak sun hours equal the daily solar irradiation in kWh/m², roughly 2-3 in northern Europe in winter, 4-5 as a yearly average in much of the US and southern Europe, and 5-6.5 in deserts and the tropics. Daily energy = kWp × peak sun hours × performance ratio.
Performance ratio
| Loss | Typical | |---|---| | Temperature | 5-12 % | | Soiling | 2-5 % | | Wiring and mismatch | 2-3 % | | Inverter | 2-4 % | | Combined PR | 75-85 % |
String sizing
- Maximum modules = inverter maximum DC voltage / Voc at the coldest expected cell temperature (Voc rises in the cold). - Minimum modules = MPPT minimum voltage / Vmp at the hottest cell temperature. For Voc 49.5 V with −0.27 %/°C at −10 °C, each module reaches 54.2 V, so a 1,000 V inverter takes at most 18 modules per string.
Worked example
A 5 kWp system with 4.5 peak sun hours and losses of 8 % temperature, 3 % soiling, 2 % wiring and a 96 % inverter has a PR of 84 % and produces about 18.9 kWh a day, 6,900 kWh a year, or 1,380 kWh per kWp.
Common mistakes
- Using air temperature instead of cell temperature. - Forgetting the cold-weather voltage rise when sizing strings, which can damage inverters. - Expecting nameplate power at noon in summer. - Using peak sun hours from a horizontal surface for a steeply tilted array without correction.
Limits
Simple models; use PVGIS, PVWatts or detailed simulation for final designs. This is not professional advice.
Esempio svolto
400 W module at 30 °C air and 800 W/m²: 286 W; 5 kWp at 4.5 PSH, PR 84 %: 6,900 kWh/year.
In breve
- Categoria: Ingegneria e costruzioni
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: NOCT cell temperature model Tc = Ta + (NOCT − 20)/800 × G and power temperature coefficient (IEC 61215, IEC 61853); performance ratio and specific yield (IEC 61724-1); string voltage limits with Voc at the lowest and Vmp at the highest cell temperature (IEC 62548, NEC 690.7)
Domande frequenti
How much power do solar panels lose in heat?
About 0.3-0.45 % per °C above 25 °C cell temperature.
How hot do solar cells get?
Typically 20-35 °C above air temperature in full sun.
What are peak sun hours?
Daily irradiation in kWh/m², equal to hours at 1,000 W/m².
What performance ratio is typical?
About 75-85 % for well-designed systems.
How many panels per string?
Inverter maximum voltage divided by cold-weather Voc, rounded down.
Is my data stored?
Solar inputs are used only for this calculation.