Office Space Calculator
Enter employees, growth over the lease, average attendance and work style, list meeting and support rooms, add a circulation factor and rent rate, and get total area, desks, area per person and rent.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1People
Enter staff and growth.
- 2Attendance
Set the share in each day.
- 3Style
Pick a work style.
- 4Rooms
List meeting and support rooms.
- 5Cost
Add rent and read the size.
Informazioni su questo strumento
The Office Space Calculator gives a first estimate of how much space a team needs before you start viewing buildings or talking to a broker. It builds the total from the people, the rooms and the space in between. You start with the number of employees and the growth you expect during the lease, because a lease usually runs five years or more and moving mid-term is expensive. An attendance percentage then turns people into desks: at 100% everyone has a seat, while a hybrid team that is in the office three days a week might plan for 60%. The work style sets the space per desk from four rules of thumb: about 80 square feet for open plan or benching, 125 for a mix of open and private space, 200 for mostly private offices and 60 for hybrid desk sharing. Meeting and support rooms are entered separately in a table with a name, a number and a size in square feet. The defaults are two small meeting rooms for four, a large room for ten, three phone booths, a kitchen and break area, reception and storage or IT. A circulation and loss factor, 20% by default, adds corridors, walls and awkward corners. Finally, a rent figure per square foot or square metre per year turns the area into a cost. The results show the office size needed, the number of desks, the area per person, and yearly and monthly rent. A breakdown table lists workstations, each room type and circulation, and a second table shows the same team in all four work styles so you can see how much a policy decision changes the floor plate. A units switch shows totals in square metres; room sizes are still typed in square feet, so convert them first if you measure in metres.
Who this is for
Start-up founders planning a first office, operations and HR managers preparing a move, and teams deciding how hybrid working should change the size of their next lease.
How to use it
1. Enter employees today and expected growth over the lease. 2. Set average attendance. Use 100% for everyone in every day and a lower figure if desks will be shared. 3. Pick the work style closest to your plan. 4. Edit the room list, adding training rooms, a quiet room, a studio or a server room as needed. 5. Set circulation and rent, then read the size, rent and both tables.
The default plan
Thirty-five employees growing by 30% become 46 people, and at full attendance that is 46 desks. At 125 square feet each the workstations need 5,750 square feet. The rooms add 1,095 and circulation adds about 1,369, so the office needs about 8,214 square feet, roughly 179 per person. At $38 per square foot per year the rent is about $312,132 a year, or $26,011 a month. Switch the units to m² and the size reads about 763 square metres; enter rent per square metre, around $409 in this case, to keep the cost the same.
Work style changes everything
The second table shows the same 46 desks and rooms in each style. Open plan needs about 5,730 square feet, mostly private offices about 12,354, and hybrid desk sharing about 4,626. Choosing private offices for everyone more than doubles the space and the rent compared with open benching.
The hybrid example
The second tab sets 60% attendance with desk sharing. That gives 28 desks, about 3,330 square feet, about 72 per person and rent of about $126,540 a year, or $10,545 a month, less than half the default plan. Check that meeting rooms and phone booths still cover the busiest days, because hybrid teams tend to come in on the same two or three days and spend more time on calls.
Usable and rentable area
Landlords usually quote rentable area, which includes a share of lobbies, lifts and shared corridors. It can be 10 to 20% more than the usable area you can actually fit desks into. Ask for the load factor and raise the circulation figure to compare buildings fairly.
Comparing options
Add a tab with + Plan for each scenario, such as a growth-only plan and a hybrid plan, and open Compare all. Print / PDF report gives a summary for a leadership meeting, and the export buttons save your work. Plans are saved in your browser without being uploaded.
Limits
Space per person figures are planning rules of thumb, not building or fire code requirements, and real layouts depend on columns, windows and the shape of the floor. Local codes set minimum space, exits and accessibility. This is not professional advice; an architect or workplace planner can test-fit a real floor plan.
Esempio svolto
Thirty-five staff growing 30% with mixed open and private desks and six room types need about 8,214 square feet, around $312,000 a year at $38 per square foot.
In breve
- Categoria: Aziende e lavoro
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: Office space planning ratios per person by work style; usable versus rentable area
Domande frequenti
How much office space per person is normal?
Rough planning figures are about 80 square feet for open plan, 125 for a mix, 200 for private offices and 60 for hybrid desk sharing, before rooms and circulation.
What is the circulation factor?
Extra space for corridors, walls and unusable corners, added as a percentage of desks and rooms. The default is 20%.
How does hybrid working change the result?
Lower attendance reduces the number of desks. The default team at 60% attendance with desk sharing needs about 3,330 square feet instead of 8,214.
Can I use square metres?
Yes for the totals. Switch units to m² and enter rent per square metre; room sizes in the table are still entered in square feet.
Why plan for growth?
Office leases often run five years or more, and moving or subletting mid-lease is costly.
What is the difference between usable and rentable area?
Usable area is where you can put desks; rentable area adds a share of common areas and is usually 10 to 20% larger.
