Network Diagram and Server Rack Planner
Draw your network, document ports and VLANs, place equipment in racks by rack unit, and check power, heat and port usage before you buy or rewire.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1Add devices
In Topology tap device types and edit their details in the side panel.
- 2Connect them
Select a device, press Connect and tap the other device; enter ports, speed and VLAN.
- 3Define VLANs
In VLANs & subnets set IDs, names, colours and subnets.
- 4Plan racks
In Racks set height and UPS capacity, then assign devices and adjust U positions.
- 5Check problems
Read port warnings, overlaps and UPS load alerts and fix them.
- 6Export
Download diagram and rack images, devices CSV and the cable list.
Informazioni su questo strumento
Small offices, labs and home networks grow cable by cable until nobody knows which port goes where. This planner keeps the network documented in one place. The topology view is a drawing of routers, firewalls, switches, servers, access points, phones, printers and cameras, with links that record the port on each end, speed, media and VLANs. Link colours follow the VLAN, fibre is drawn thicker and wireless dashed, and a badge on each device shows used versus available ports. The rack view places rack-mountable devices by unit height, warns about overlaps and devices that do not fit, and adds up power, heat in BTU per hour and current at your mains voltage, compared with your UPS capacity. A VLAN table checks each subnet and lists member devices, and the devices table warns when an IP address is outside the subnet of its VLAN. Exports include SVG and PNG drawings, rack elevations and a cable schedule as CSV.
Who this is for
IT administrators of small businesses and schools, managed service providers documenting client sites, homelab enthusiasts, and students of networking courses.
Topology
Tap a device type to add it, drag it into place and edit name, model, IP address, port count, power, rack height and PoE. Press Connect and tap the other device to add a link, then fill both port numbers, speed (100M to 100G or Wi-Fi), VLAN or trunk list and media. Problems such as two links on one port, more links than ports or a port number above the device's port count are listed above the tabs.
Racks
Create racks of 6U to 48U with a name, UPS capacity in watts and mains voltage. Assign each rack-mountable device to a rack; the first free slot from the top is chosen and you can move it up or down one unit or type a U position. U1 is at the bottom, as in the EIA-310 standard. The elevation drawing updates live; the summary shows used and free units, total watts, BTU/h, amps and UPS load with a warning above 80 %.
VLANs and subnets
Each VLAN has an ID from 1 to 4094, a name, a colour and an IPv4 subnet. The card shows network address, usable host range, host count and mask, and lists the devices connected on that VLAN.
Tables and exports
The devices table shows ports in use, power and rack position; the links table edits ports and VLANs in bulk. Downloads: diagram SVG and PNG, rack SVG and PNG, devices CSV and a numbered cable list CSV for labelling both ends of each cable.
Worked example
The sample office rack holds a firewall, a 24-port PoE core switch, a patch panel, a 2U hypervisor, a 2U NAS and a 2U UPS in a 24U rack: 9U used, 15U free, 630 W, 2,150 BTU/h and 2.7 A at 230 V, which is 47 % of the 1,350 W UPS. The core switch uses 8 of 24 ports across VLANs 10, 20 and 30.
Limits
Power figures are the values you enter; use the nameplate or measured draw for accuracy, and remember start-up peaks. The planner documents a design but does not scan or configure devices. Rack depth, weight, cooling airflow and front-to-back placement are not modelled.
Esempio svolto
24U rack: firewall, PoE switch, patch panel, hypervisor, NAS, UPS → 9U used, 630 W, 2,150 BTU/h, 2.7 A at 230 V, 47 % of a 1,350 W UPS.
In breve
- Categoria: Sviluppo e dati
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: EIA-310 rack units, IEEE 802.1Q VLAN IDs and 1 W = 3.412 BTU/h
Domande frequenti
How is heat calculated?
Almost all electrical power becomes heat, so the planner multiplies watts by 3.412 to get BTU per hour for sizing cooling.
Where is U1?
At the bottom of the rack, following EIA-310 numbering. Heavy equipment such as UPS units should sit low.
Can a link carry several VLANs?
Yes. Type a comma list such as 10,20,30 for a trunk; the first VLAN sets the line colour.
Why does a device show a red badge?
It has more links than ports. Raise the port count or move links to another device.
Can I print labels for cables?
Download the cable list CSV; each link has a number and both ports, ready for a label printer or spreadsheet.
Where is my plan stored?
In local storage in this browser, with undo; Save file creates a backup you can open elsewhere.