Gage R&R Calculator (Measurement System Analysis)

Enter or paste the readings from a crossed gauge study with 2 to 30 parts, 2 to 5 operators and 2 to 5 trials, add the specification limits if you want percent of tolerance, and get the ANOVA table, variance components, percent study variation and contribution, the number of distinct categories, the AIAG average and range results and three charts.

Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo

…

Come si usa

  1. 1
    Study

    Set parts, operators, trials and gauge name.

  2. 2
    Readings

    Type or paste every measurement.

  3. 3
    Limits

    Add specification limits for percent of tolerance.

  4. 4
    Options

    Pick 6 or 5.15 sigma and the interaction level.

  5. 5
    Report

    Read the verdict and print the results.

Informazioni su questo strumento

The Gage R&R Calculator analyses a crossed measurement system study, in which every operator measures every part several times. Its purpose is to split the spread you see in the readings into the part of it that comes from the parts themselves and the part that comes from the measuring process, which is further divided into repeatability, the variation when one person measures the same part again, and reproducibility, the variation between people. The study panel takes the name of the gauge or characteristic, the number of parts, operators and trials, the operators' names, optional upper and lower specification limits, the multiplier for study variation (6 sigma as in the AIAG fourth edition, or 5.15 sigma for older practice) and the significance level for keeping the part by operator interaction. The measurement grid then has one row per part and one column per operator and trial. The main results use two-way ANOVA. The calculator tests the part by operator interaction against repeatability with an F test; if its P value is above the chosen level, the interaction is pooled into repeatability and the table is recomputed without it, otherwise it is kept and counted within reproducibility. From the mean squares it estimates variance components and reports, for each source, the variance, standard deviation, study variation, percent contribution, percent study variation and, when limits are given, percent of tolerance. It also gives the number of distinct categories, 1.41 times the ratio of part standard deviation to gauge standard deviation, rounded down, and a verdict against the 10 and 30 percent guidelines.

Who this is for

Quality engineers qualifying a new gauge, metrology and inspection staff checking a measurement system before a capability study, Six Sigma belts in the Measure phase, supplier quality engineers reviewing a PPAP submission, and students working through measurement system analysis exercises.

How to use it

1. Name the gauge and set the number of parts, operators and trials. 2. Enter the readings in the grid or paste them from a spreadsheet. 3. Add the upper and lower specification limits to see percent of tolerance. 4. Choose 6 or 5.15 sigma and the level for keeping the interaction. 5. Read the verdict, check the charts and print the report.

Pasting data

Two layouts are read. A wide layout has one row per part with the trials of operator 1, then operator 2 and so on; any extra leading columns, such as a part number, are dropped. A long layout has part, operator and value on each line, with an optional fourth column, and the calculator works out the parts, operators and trial count from the distinct names. Commas, tabs and semicolons all work as separators.

What the sample shows

The sample is a bore diameter gauge on line 2: 10 parts, three operators named Anna, Ben and Chris, three trials each and limits of 0.30 and 1.20, a tolerance of 0.9. The interaction has a P value far below 0.05, so it is kept. Total Gage R&R is 31.6 percent of study variation and 42.5 percent of tolerance, with repeatability at 13.5 percent and reproducibility at 28.6 percent, most of it from the interaction at 25.1 percent. The number of distinct categories is 4. The verdict is not acceptable: improve the measurement system. The average and range method on the same data gives 22.3 percent of total variation and 6 categories because it cannot separate the interaction, which is why the ANOVA figures lead.

Charts and exports

The first chart compares percent contribution and percent study variation for Gage R&R, repeatability, reproducibility and part. The range chart plots the range of each part for each operator against an upper control limit of D4 times the average range, and any range above it is listed as a reading to check. The third chart shows every reading by part with a line through each operator's averages. The data, ANOVA and component tables download as CSV, XLSX or JSON, the charts as PNG, SVG or PPTX, and Print report collects everything on one page. Studies autosave in this browser with Undo, Redo, named saves and JSON export.

Limits

The average and range method uses the AIAG constants and only runs for 2 or 3 trials, 2 or 3 operators and 2 to 10 parts; larger studies show the ANOVA results alone. The 10 percent and 30 percent guidelines and the target of at least 5 distinct categories are AIAG guidance, and whether a marginal gauge is fit for use depends on the application. Every cell must hold a number before results appear. The results describe your study data; they are not metrology or calibration advice and do not replace a calibrated reference.

Esempio svolto

Bore gauge sample, 10 parts x 3 operators x 3 trials, tolerance 0.9: GRR 31.6% of study variation, 42.5% of tolerance, 4 distinct categories, interaction kept.

In breve

Domande frequenti

Which method should I trust, ANOVA or average and range?

ANOVA, where both are shown. It separates the part by operator interaction, while the average and range method folds it into the other terms. In the sample the two give 31.6 and 22.3 percent.

What does pooling the interaction mean?

If the part by operator F test gives a P value above your chosen level, the interaction is treated as noise and merged into repeatability. You can choose 0.05, 0.10 or 0.25 as that level.

Do I need specification limits?

No. Without them you get percent study variation and contribution. With both limits the calculator also shows percent of tolerance, using study variation divided by the upper minus lower limit.

What is the number of distinct categories?

It estimates how many groups of parts the gauge can reliably tell apart: 1.41 times part standard deviation over gauge standard deviation, rounded down. AIAG guidance asks for 5 or more.

Should I use 6 or 5.15 sigma?

The AIAG fourth edition uses 6 sigma, which covers about 99.73 percent of a normal spread. Choose 5.15 only to match older reports. Percent study variation and contribution do not change.

Where are my measurements stored?

In this browser only, saved automatically as you type. Use the project export to keep a JSON copy, or the table downloads for a spreadsheet record.

Completamente gratisNessun costo, nessuna registrazione
I file restano privatiTutto funziona nel tuo browser
Facile nella tua linguaDisponibile in molte lingue