First Article Inspection Report (AS9102 Forms 1, 2 and 3)
Balloon a drawing by tapping it, enter each requirement and measured result, get pass or fail per characteristic, link nonconformances and print all three AS9102 forms.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1Fill in Form 1
Enter the part, revision, drawing, organisation and whether it is a full or partial, detail or assembly FAI.
- 2List materials and processes
Add each material, special process and functional test with its specification and certificate on Form 2.
- 3Balloon the drawing
Load the drawing image and tap each characteristic to place numbered balloons.
- 4Enter requirements
Give each balloon its requirement type, nominal and tolerance or limits, or the note text.
- 5Record results
Type the measured values or attribute results, or import a CMM report CSV.
- 6Resolve and print
Add NCR numbers for failures, clear the checks and print all forms or save PDF.
Informazioni su questo strumento
Aerospace customers ask for a first article inspection the first time a supplier makes a part, after a change to the design or process, after two years without production, and whenever the customer requires one. AS9102 sets out what the report contains in three forms. Form 1 identifies the part, its revision, the drawing and the organisation, and for assemblies lists the sub-parts with their own reports. Form 2 lists every raw material, special process and functional test with its specification and certificate of conformance. Form 3 lists every design characteristic on the drawing with a balloon number, the requirement, the measured result and any nonconformance. Building these by hand means numbering bubbles on a printed drawing, copying tolerances into a spreadsheet and checking each result by eye. This tool does the bookkeeping. You load the drawing as an image and tap to place numbered balloons, enter each characteristic as nominal and tolerance, limits, a maximum or minimum, or an attribute note, and type the reading. Each result is judged against its limits, failures are flagged until a nonconformance number is entered, and the three forms print with the ballooned drawing.
Characteristics and results
Choose the requirement type for each balloon. Nominal and tolerance covers most dimensions, such as 10.000 +0.015 -0.000 mm. Limits suit a length given as 119.8 – 120.2, a maximum suits flatness or roughness, and a minimum suits hardness or thread depth. Attribute covers notes such as edge breaks or part marking, which pass on words like conforms or OK and fail on NC or reject. When a feature is measured in several places, type all readings separated by commas; every one must be inside the limits for a pass. A CMM report saved as CSV with balloon, nominal, plus, minus and actual columns can be imported in one step.
Balloons on the drawing
AS9102 expects every characteristic to be traceable to the drawing. Export the drawing page to PNG or JPG and load it; the image stays on your device and is saved separately from the report so it never blocks saving. In add mode each tap creates the next balloon at that spot; in move mode a tap moves the selected balloon. Failed balloons are drawn in red. Without an image the balloons sit on a blank sheet, which still gives a numbered layout.
Worked example
The sample is a full detail FAI for an aluminium actuator bracket at revision D, serial 0001. Form 2 lists the 7075-T7351 plate to AMS 4078, a chromic acid anodise from a NADCAP source and penetrant inspection, each with a certificate number. Form 3 has eight balloons. The bore reads 10.008 against 10.000 +0.015/-0.000 and passes, the hole spacing of 40.03 is inside ±0.05, flatness of 0.021 is under its 0.05 maximum, and both attribute notes conform. The thickness, 6.35 ±0.10, measures 6.47, which is 0.02 over the limit, so it fails and carries NCR-2026-311. The report shows seven passes, one fail and nothing open, and because a nonconformance exists, Form 1 field 19 is ticked to say the FAI contains documented nonconformances. Deleting the NCR number brings back a warning that field 11 needs one.
Limits
This is a working tool that follows the AS9102 rev C field numbers, not the SAE standard itself and not a customer approval. It does not read PDF drawings directly, recognise dimensions automatically or replace a customer portal such as Net-Inspect where that is mandated. Tolerance stacks, GD&T datums and measurement uncertainty are not evaluated; record the gauge and method in the comments.
Esempio svolto
Eight balloons: 7 pass and 1 fail (thickness 6.47 against 6.35 ±0.10, NCR-2026-311), 0 open; Form 1 field 19 marks documented nonconformances.
In breve
- Categoria: Aziende e lavoro
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: SAE AS9102 Aerospace First Article Inspection Requirement
Domande frequenti
When is a first article inspection needed?
Under AS9102, for a new part, after a change to the design, the manufacturing source, the process, tooling or location, after a lapse of two years in production, and whenever the customer asks. A partial FAI covers only the affected characteristics.
How do I do a partial FAI?
Press Partial FAI from this one. It copies the characteristics with empty results, sets Form 1 to partial and fills the baseline part number with revision. Delete the characteristics the change did not affect and enter the reason.
Can I balloon a PDF drawing?
Convert the drawing page to PNG or JPG first, for example with a PDF to image tool, and load the image. Use a resolution that keeps the numbers readable when printed.
What counts as a characteristic?
Every design requirement on the drawing and in referenced specifications: dimensions, tolerances, notes, surface finish, marking and material or process callouts. Each gets its own balloon number.
What happens with a failed result?
It is marked FAIL in red and the report asks for a nonconformance number in field 11. Raise the NCR in the non-conformance report builder on this site and record the customer's disposition.
Where is my data kept?
In this browser only. Export file saves the reports as JSON; the drawing image is kept separately on the device and is included in the printed or downloaded report.