Engine Ground Run Log
Record engine ground runs by tail and engine, check peak EGT, N1 and oil pressure against your limits, chart EGT by run and print a run sheet.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1Set limits
EGT, oil, N1 from manual.
- 2Log run
Tail, engine, reason, time.
- 3Enter peaks
EGT, N1, oil, vibration.
- 4See result
Within limits or EXCEEDED.
- 5Print record
With signature lines.
Informazioni su questo strumento
The Engine Ground Run Log is a running record of every engine run you carry out or watch, with an automatic check against the limits you set for the engine type. First list your tail numbers and enter four limits: the EGT or ITT maximum (750°C to start), the minimum and maximum oil pressure at power (25 and 100 psi) and the maximum N1 or rpm (101). Each run then records the tail, the engine position from 1 or left to 4, single or APU, the date, the reason for the run, its length in minutes, the highest power setting reached, peak EGT or ITT, peak N1 or rpm, oil pressure and temperature, a vibration figure, findings or leaks and who ran it. As soon as a run is saved it is marked either Within limits or EXCEEDED with the parameter named. The summary counts runs, total run time in hours and exceedances, a line chart plots peak EGT run by run for each tail against the limit, and every run can be printed as a ground run record with a reading-versus-limit table and signature lines for the person running the engine and the fire cover or observer.
Who this is for
Licensed engineers authorised for engine runs who want their own record of runs and readings, trainees working towards a run-up authorisation, flight line supervisors keeping a quick personal tally, and instructors using real-looking data in powerplant lessons.
How to use it
1. Open the settings, list your registrations one per line and set the four limits from the engine maintenance manual. 2. Press Load example if you would like to see two sample runs first, one within limits and one with an EGT exceedance. 3. Add a run: pick the tail and engine position, the date and the reason, such as a leak check after a component change. 4. Enter the run time, the highest power setting (idle, partial power or take-off and maximum) and the peak readings. 5. Note any findings or leaks and the name of the person who ran the engine. 6. Check the Limits column; an exceedance is shown in capitals with the parameter that went over. 7. Print the run record for the work pack or export the log as CSV.
What is checked and what is not
Three things are tested automatically. Peak EGT or ITT is compared with the single limit you set, peak N1 or rpm with the maximum, and oil pressure at power with the band between the minimum and maximum. A blank reading is skipped rather than failed. Oil temperature and vibration are recorded and printed but not tested, because their limits often depend on the phase of the run and the instrument used. Real engines also have time-limited transient limits, such as a higher EGT allowed for a few seconds during a start; the log uses one figure, so a reading above it is flagged for you to judge against the manual's full table.
The chart and summary
The line chart shows each tail's peak EGT or ITT in the order the runs were logged, with the limit drawn across it. A slow upward drift on one aircraft across several runs at similar power can be worth a conversation with the powerplant team, even while every run is inside the limit. The summary tiles keep the total number of runs, the accumulated run time and the count of exceedances in view.
The ground run record
Each run's printable record repeats the tail, engine, date, reason, run time and power, then sets out a small table of parameter, reading and limit for EGT, N1, oil pressure, oil temperature and vibration. The overall result is printed in bold, followed by the findings and two lines for signatures and dates. It is a tidy way to write up a run for your own file or to hand to a supervisor.
Searching, exporting and backups
Search finds runs by any text or number, such as a tail or a reason. Export the table as CSV for a spreadsheet, or save a full JSON backup that can be imported again on another device. Everything is held in your browser; no run data leaves it unless you export it.
Limits
One fixed limit per parameter cannot represent every engine's start, transient and steady-state tables, and the log does not know your engine type. The engine manual's run-up procedure, limits and exceedance actions always apply, and runs must only be carried out by people authorised to do so. This is a personal and training log, not an approved maintenance record or engine monitoring system, and not powerplant advice.
Esempio svolto
With the limit at 750°C, a vibration survey on ZZ201 engine 1 that peaked at 758°C and 100.5% N1 is marked EXCEEDED: EGT, while a 12 minute leak check on G-ABCD at 690°C is within limits; the two runs total 0.6 h.
In breve
- Categoria: Ingegneria e costruzioni
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: Engine ground run records against manual limits
Domande frequenti
Which readings are checked against limits?
Peak EGT or ITT, peak N1 or rpm, and oil pressure against a minimum and maximum.
Where do the limits come from?
You enter them in the settings from the engine maintenance manual; the defaults are only placeholders.
Does it handle APU runs?
Yes, APU is one of the engine positions you can choose.
Can I print a record of a single run?
Yes, each run prints as a ground run record with readings, limits, findings and signature lines.
Is oil temperature checked?
It is recorded and printed but not compared with a limit.
Does this replace the aircraft's technical records?