Ceiling Fan Size and Downrod Calculator
List your rooms with ceiling heights to get fan count, blade size, mount type, downrod length, blade height checks and yearly running cost.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1Add rooms
Enter each room's name, length, width and ceiling height.
- 2Add fan models
In Fan models, enter diameter, airflow and watts from each fan's label and its price.
- 3Assign models
Choose a model for each room and set the hours a day it runs.
- 4Read the sizes
Open Fan sizes for fan count, suggested size, mount, rod, blade height and warnings.
- 5Check the plan
Use Room plan to see fan positions and blade circles in each zone.
- 6Tune the rules
Edit size bands, heights, clearances and stock rods in Size guide, then print or save.
Informazioni su questo strumento
A fan that is too small for a room barely stirs the air, and one hung too high or too close to the ceiling moves far less air than its box promises. The US Department of Energy suggests blades about 7 to 9 feet above the floor with clearance from the ceiling and walls, and sizes that grow with the room. This planner applies those rules room by room. Enter each room's length, width and ceiling height. Large or long rooms are split into zones so that no fan has to serve more than the area you allow, and each zone gets a suggested blade diameter from a size table you can edit. The tool then works out whether you need a flush (hugger) mount, the standard short rod or a longer downrod, picks the longest stock rod that still leaves the blades at your target height, and flags rooms where the blades would be too low, too close to the ceiling or too near a wall. Add the fan models you are considering with their airflow and watts from the label to compare cubic feet per minute per watt, and see the electricity cost for the hours and season you use them.
Size bands
The default bands are the sizes commonly used by fan sellers: around 29 to 36 inches for rooms up to 75 square feet, 36 to 42 inches up to 144, 44 to 50 inches up to 225 and 50 to 56 inches up to 400. Change any band, or add one, in the size guide. In metric mode bands are in square metres and sweep in millimetres, which suits markets that sell 900, 1200 and 1400 mm fans.
Downrods and heights
The downrod length is the ceiling height minus your target blade height minus the fan's own height from ceiling to blades. The result is rounded down to the nearest stock length you list, so blades are never lower than planned. If even a flush mount leaves the blades low, the room is flagged.
Several fans in one room
A great room of 640 square feet with a 400 square foot limit gets two fans, each centred in its own zone. The room plan draws the zones, fan positions and blade circles so you can check spacing from walls and lights.
Running cost and efficiency
Running cost uses the watts at the speed you enter, the number of fans, hours per day, days per season and your electricity price.
Limits
This is a sizing aid, not an electrical design. It does not check box ratings, wiring, sloped-ceiling adapters or local code. Use a fan-rated electrical box and follow the maker's instructions, and ask an electrician if you are unsure.
Esempio svolto
A living room 16 by 18 feet is 288 square feet, so one fan in the 50 to 56 inch band. The ceiling is 9 feet (108 inches); with a target blade height of 8.5 feet (102 inches) and a fan that drops 12 inches without a rod, there is no room for a rod, so a flush mount puts the blades at 96 inches, 8 feet, which passes the 7-foot minimum. A 20 by 32 foot great room with a 14-foot ceiling is 640 square feet: two fans of 50 to 56 inches, each with a 48-inch downrod, blades at 9 feet. A 52-inch DC fan rated 5,200 cfm at 30 watts gives 173 cfm per watt and costs about 7 dollars for a 150-day season at 10 hours a day and 0.16 per kWh.
In breve
- Categoria: Casa e vita
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: US Department of Energy Energy Saver: fans for cooling (size, height and placement); ENERGY STAR ceiling fan specification for airflow efficiency
Domande frequenti
What size ceiling fan do I need for a 12 by 12 room?
A 144 square foot room falls in the 36 to 42 inch band of the default table. Many people choose 42 or 44 inches for a bedroom; check that blade tips stay at least 18 inches from walls.
How long should my downrod be?
Subtract the target blade height and the fan's own height from the ceiling height, then pick the nearest stock rod that is not longer. The calculator does this using the rod lengths you list.
How low can fan blades be?
Fan makers and the Department of Energy guidance put the blades at least 7 feet above the floor. Set your own minimum and the tool warns when a room cannot meet it.
When do I need two fans?
When a room is larger than the area one fan should serve, or long and narrow. The default limit is 400 square feet per fan; the tool splits the room into near-square zones and centres a fan in each.
What does cfm per watt tell me?
It is the airflow delivered for each watt of electricity, the efficiency figure used by ENERGY STAR. DC motor fans often reach much higher values than older AC fans of the same size.
Does it work for outdoor patios?
Yes for sizing and height. Choose a fan with a damp or wet rating for covered or exposed locations; the calculator does not check ratings.