Home Backup Generator Sizing Calculator

List your appliances with running and starting watts, pick essentials or everything, and get a generator size, load, run time per tank and fuel for a power cut.

Läuft in Ihrem Browser. Ihre Dateien verlassen nie Ihr Gerät. So prüfen Sie es

…

So geht's

  1. 1
    List the appliances

    Running and starting watts with hours a day.

  2. 2
    Mark the essentials

    Choose essentials only or everything.

  3. 3
    Set headroom

    20% is a common margin.

  4. 4
    Pick type and fuel

    Portable, inverter or standby.

  5. 5
    Read the size

    Recommended watts and load.

  6. 6
    Plan the fuel

    Tank run time and fuel for an outage.

Über dieses Tool

A generator that is too small trips the moment a freezer compressor or a sump pump starts. One that is too big burns fuel all day at light load. This calculator sizes a backup generator the way electricians do. List each appliance with its running watts and starting watts from the rating plate or manual, the quantity, whether it is essential and how many hours a day it actually runs. Motor loads such as fridges, pumps, furnace fans and air conditioners draw two to three times their running power for a second or two when they start. The size you need is the running total plus the single largest start-up surge, because sensible owners start motors one at a time. The tool adds your chosen headroom to the running total, checks the surge rating of each standard size and suggests the smallest one that fits, or tests a model you are looking at. It then estimates fuel use from the generator's rated size and the average load over the hours you run it, so you can see litres per hour, run time on one tank, fuel for a three-day outage and how many days your stored fuel would last. Notes cover transfer switches and carbon monoxide safety.

Sizing rule

Required running watts = sum of running watts × (1 + headroom). Required starting watts = sum of running watts + the largest single (starting − running). The generator's surge rating is its running rating × the surge ratio from the spec sheet, typically 1.2-1.3.

Typical appliance watts

| Appliance | Running W | Starting W | |---|---|---| | Fridge-freezer | 150 | 1,200 | | Sump pump 1/2 hp | 800 | 2,100 | | Furnace blower | 500 | 1,300 | | Window air conditioner | 1,200 | 3,600 | | Well pump | 1,000 | 2,000 | | Microwave | 1,000 | 1,000 |

Fuel model

Fuel per hour = idle burn × rated kW + marginal use × output kW. Petrol uses about 0.08 L per rated kW at idle plus 0.4 L per kWh produced. Inverter models halve the idle burn because they throttle down at light load. Diesel, LPG and natural gas have their own factors.

Worked example

The essential circuits are a fridge-freezer, a chest freezer, a sump pump, the furnace fan and pump, LED lights and a router. They run at 1,830 W together. The sump pump adds the largest start-up surge of 1,300 W, so the peak is 3,130 W. A 3,500 W generator with a 1.25 surge ratio covers both, at 52% load. These loads use 11.7 kWh a day. Run for 12 hours, the generator burns 0.67 L of petrol an hour and 8.05 L a day, so a 23 L tank lasts about 34 hours and 40 L stored covers almost five days. Powering everything listed instead needs 4,650 W running and 7,050 W at start-up, which points to a 7,500 W unit.

Limits

This is a planning estimate, not an electrical design. Wattages vary by model, so read the rating plates. A transfer switch or interlock must be installed by a licensed electrician to local code. Fuel figures are not manufacturer data.

Rechenbeispiel

Fridge, freezer, sump pump, furnace, lights and router: 1,830 W running, 3,130 W peak, 3,500 W generator, 8.05 L petrol a day.

Kurzinfos

Häufig gestellte Fragen

What is the difference between running and starting watts?

Running watts are what an appliance draws steadily. Starting watts are the brief surge a motor needs to get going, often two to three times higher.

Why add only the largest surge?

Motors rarely start at the same instant. If you switch big loads on one at a time, only one surge happens at once, which is the standard sizing method.

Should I choose an inverter generator?

Inverters give clean power for electronics and use far less fuel at light load, but they cost more per watt and are rarely larger than about 7 kW.

How do I connect a generator to my house?

Through a transfer switch or an approved interlock with an inlet box, fitted by a licensed electrician. Never back-feed through a socket.

How much fuel should I store?

Enough for the outages you expect, stored safely in approved cans with stabiliser and rotated every six to twelve months.

Can I run the generator all day?

Most portable units can, but you will save fuel by running them in blocks, for example a few hours morning and evening to keep freezers cold.

Völlig kostenlosKeine Kosten, keine Anmeldung
Dateien bleiben privatAlles läuft in Ihrem Browser
Einfach in Ihrer SpracheIn vielen Sprachen verfügbar