Blasting Design Calculator
Enter hole diameter, bench height, explosive and rock density to get a first bench blast pattern with charge and powder factor, or estimate ground vibration from distance and charge per delay with the USBM scaled-distance law.
Läuft in Ihrem Browser. Ihre Dateien verlassen nie Ihr Gerät. So prüfen Sie es
…
So geht's
- 1Choose design or vibration
Mode.
- 2Enter hole and bench
Diameter and height.
- 3Enter densities
Explosive and rock.
- 4Set spacing ratio
S/B.
- 5Read pattern and charge
Or PPV and charge limit.
Über dieses Tool
Bench blasting in quarries and open-pit mines is designed around the burden, the distance from a blast hole to the free face. Too large a burden leaves the rock unbroken and throws energy into ground vibration; too small a burden throws rock and wastes explosive. Konya's empirical formula relates burden to hole diameter and the densities of explosive and rock, and the other pattern dimensions follow as ratios of the burden. This calculator lays out a first pattern, works out the charge per hole and the powder factor, and in a second mode estimates peak particle velocity at a neighbour's building from the charge fired per delay.
Who this is for
Shotfirers, quarry managers, mining and civil engineers, drill and blast students and environmental officers.
Pattern ratios (Konya)
| Dimension | Typical | |---|---| | Burden B | (2·SGe/SGr + 1.5) × De | | Spacing S | 1.0-1.4 B (1.15 B staggered) | | Subdrill J | 0.3 B | | Stemming T | 0.7 B | | Stiffness ratio H/B | 3 or more for good fragmentation | With B in metres and De in millimetres, multiply by 0.012.
Explosives and rock
ANFO has a density of about 0.80-0.85 g/cm³; emulsions and heavy ANFO 1.1-1.3. Limestone is about 2.6 g/cm³, granite 2.65-2.7 and iron ore over 3.5. Denser explosive allows a larger burden.
Charge and powder factor
Charge per metre = explosive density × π × De² / 4. Charge per hole = charge per metre × (hole depth − stemming). Powder factor = charge / (B × S × bench height), in kg/m³ or kg/t. Quarries typically use 0.3-0.6 kg/m³; hard rock mines up to 1 kg/m³.
Ground vibration
Scaled distance SD = D / √W, with D the distance in metres and W the maximum charge per delay in kg. The USBM average law gives PPV = 1,140 × SD^−1.6 mm/s. Site-specific constants from monitoring are far better. Common limits for houses are 5-15 mm/s depending on frequency and country; BS 7385 and USBM RI 8507 give frequency-dependent criteria.
Worked example
A 102 mm hole on a 10 m bench with ANFO (0.85) in limestone (2.6) gives a burden of 2.64 m, spacing 3.16 m at 1.2 B, subdrill 0.79 m and stemming 1.85 m. Each hole takes 62 kg and breaks 83 m³, a powder factor of 0.75 kg/m³. At 300 m, 62 kg per delay gives about 3.4 mm/s; to stay below 10 mm/s, no more than 242 kg should fire per delay.
Common mistakes
- Increasing the burden on the front row without checking the face profile, which risks flyrock or toe problems. - Too little stemming, which vents gas and throws rock. - Firing several holes on one delay and multiplying the charge per delay. - Using the generic vibration law without site monitoring.
Limits
First estimates only. Blasting must be designed and supervised by licensed persons under local regulations. This is not professional blasting advice.
Rechenbeispiel
102 mm, 10 m bench, ANFO in limestone: burden 2.64 m, 62 kg per hole, 0.75 kg/m³.
Kurzinfos
- Kategorie: Technik & Bau
- Läuft in Ihrem Browser, ohne Anmeldung, ohne Upload.
- Ihre Eingaben bleiben auf Ihrem Gerät.
- Auf Englisch verfügbar.
- Inhalt zuletzt geprüft:
- Offizielle Quelle: Konya and Walter, Surface Blast Design (burden B = (2·SGe/SGr + 1.5)·De, subdrill 0.3·B, stemming 0.7·B); USBM RI 8507 (Siskind et al. 1980) scaled distance and PPV = K·(D/√W)^−β with K = 1,140 and β = 1.6 as the average site law (mm/s, m, kg)
Häufig gestellte Fragen
How do I calculate burden?
B = 0.012 × (2·SGe/SGr + 1.5) × De(mm) metres, by Konya.
What spacing should I use?
About 1.0-1.4 times the burden.
What is powder factor?
Explosive mass per volume or tonne of rock broken.
How is ground vibration estimated?
From scaled distance D/√W and a site law.
What vibration limit applies to houses?
Often 5-15 mm/s, depending on frequency and local rules.
Is my data stored?
Blast designs stay on your device; nothing is uploaded.
