Smart Thermostat Schedule Planner

Build heating periods for weekdays and weekends, add smart radiator valve offsets per room and see the average temperature, yearly saving and a schedule to copy.

S'executa al teu navegador. Els fitxers mai no surten del dispositiu. Mira com comprovar-ho

…

Com es fa

  1. 1
    Enter your heating cost

    The yearly bill at comfort all day.

  2. 2
    Describe the house

    System, how fast it cools and outdoor temperature.

  3. 3
    Set comfort and setback

    Plus the early start time.

  4. 4
    Add heating periods

    Weekdays, weekends or single days.

  5. 5
    Add room offsets

    Share of floor area and degrees up or down.

  6. 6
    Copy the schedule

    Download it and enter it in your app.

Sobre aquesta eina

A smart thermostat only saves money if its schedule is good. Heating an empty home all day, or warming the spare room to the same temperature as the lounge, wastes more energy than most people expect. This planner lets you design the week first and see what it is worth. Set a comfort temperature, which is also the baseline for savings, and a setback temperature for nights and empty hours. Add heating periods for weekdays, weekends or single days, each with its own start, end and target, and an early start so the house is warm when the period begins. If you have smart radiator valves, list the rooms with their share of the floor area and how many degrees above or below the main schedule each one runs. Holiday mode covers the days the home is empty. The tool builds a half-hour profile for the whole week and charts Monday, Saturday and Sunday. It works out the average target temperature, adjusts for the way houses cool slowly during a setback, and estimates the saving against keeping the comfort temperature day and night. It also produces a day-by-day list of temperature changes to type into the thermostat app.

How the saving is estimated

Heat loss is roughly proportional to the gap between indoor and outdoor temperature. The saving fraction is the drop in average indoor target, multiplied by how much of a setback the building actually reaches, divided by the comfort-to-outdoor gap.

| Building | Share of a setback realised | |---|---| | Light (timber frame, flat) | 85% | | Medium (cavity brick) | 70% | | Heavy (solid stone or concrete) | 55% |

Room offsets apply during heating periods, weighted by floor area. Holiday mode adds the saving of dropping to its own temperature for the days away. The total is capped at 60%.

Heat pumps are different

A heat pump is most efficient at low, steady flow temperatures. After a deep setback it has to run hotter to recover, which lowers its efficiency. When the setback is more than 3 °C below comfort the tool reduces the schedule saving by 30% for heat pumps. A setback of 1-2 °C usually works better.

Worked example

A cavity brick house costs £1,100 a year to heat at 20 °C all day, with a 7 °C average outdoor temperature. The schedule runs 06:30-08:30 and 17:00-22:30 on weekdays and 07:30-23:00 at weekends, with a half-hour early start and a 16 °C setback. That keeps the home at comfort for 74.5 hours a week and gives an average target of 17.86 °C. Room offsets bring it to 17.35 °C. With 14 days of holiday mode the saving is 16.2%, about £178 a year. Each extra degree of comfort would cost about £71. The same schedule with a heat pump and an £850 bill saves £101. Raising the setback to 18.5 °C gives £78 but keeps the pump running efficiently.

Limits

These are estimates, not metered results. Real savings depend on insulation, draughts, how quickly the heating recovers and whether people change the schedule. Do not let rooms used by babies, older people or anyone unwell fall below 18 °C. A smart thermostat cannot fix damp or a faulty boiler.

Exemple resolt

Weekday 06:30-08:30 and 17:00-22:30 at 20 °C, 16 °C setback, £1,100 bill: about £178 a year saved (16.2%).

En resum

Preguntes freqüents

Does turning the heating down at night really save money?

Yes. A house loses heat in proportion to how warm it is inside, so lower average temperatures mean less fuel, even after the energy used to warm up again.

What setback temperature should I use?

For a boiler, 15-17 °C at night is common. For a heat pump, stay within about 2 °C of your daytime temperature.

What is an early start?

Smart thermostats learn how long the house takes to warm and switch on early so it reaches the target at the start time. The tool adds that time to each period.

How do smart radiator valves help?

They let bedrooms and spare rooms run cooler than the living room. The tool weights each room's offset by its floor area.

How much does holiday mode save?

In the example, 14 days away at 12 °C is worth about £21 a year. Longer winter trips save more.

Will the house get damp if I set it too low?

Long periods below about 16 °C raise the risk of condensation and mould, especially in older homes. Keep the setback moderate and ventilate.

Totalment gratisSense cost, sense registre
Els fitxers es mantenen privatsTot funciona al teu navegador
Fàcil en el teu idiomaDisponible en molts idiomes