Room Acoustics Analyzer
Play an exponential sine sweep, record it, get the room's impulse response and decay times, then compare treatment and calculate room modes.
S'executa al teu navegador. Els fitxers mai no surten del dispositiu. Mira com comprovar-ho
…
Com es fa
- 1Set up
Place the speaker and microphone, close windows, name the measurement and set the sweep length and range.
- 2Measure
Press Play sweep and record and stay quiet until the result appears; or import a sweep recording or impulse response.
- 3Read the decay
Check RT60, EDT, T20, T30 and the decay range, and the octave band table.
- 4Compare
Tick saved measurements to overlay their frequency responses before and after treatment.
- 5Check room modes
Enter length, width and height to list modes and see pile-ups and gaps.
- 6Plan treatment
Choose the room use to get absorption estimates, and export the CSV or impulse response WAV.
Sobre aquesta eina
A room that sounds boomy, echoey or dead usually has a measurable reason: reverberation that lasts too long in some bands, or standing waves between parallel walls. Acousticians measure this with a sine sweep: a tone that rises smoothly from deep bass to high treble is played through a speaker and recorded. Dividing out the known sweep leaves the impulse response, the room's acoustic fingerprint, from which the decay time and frequency response follow. Free desktop programs do this well but need installation and setup. This analyzer runs the whole chain in the browser: it plays an exponential sweep through your speaker while recording with your microphone, deconvolves the recording, and computes the energy decay curve by Schroeder backward integration. From that curve it reports the early decay time EDT and the reverberation times T20 and T30, both extrapolated to a 60 dB decay as in ISO 3382, broadband and in octave bands from 125 Hz to 4 kHz. You can also play the sweep on another system and import its recording, or import an existing impulse response.
Getting a clean measurement
The sweep should be clearly louder than the room noise without distorting the speaker. The decay range shown with the results is how far the decay fell above the noise floor; T20 needs at least 35 dB and T30 needs at least 45 dB, otherwise the value is left blank rather than guessed. Close windows, switch off fans, and repeat a measurement at two or three microphone positions, because a single position is affected by local modes.
Comparing before and after
Each measurement is saved with its name, date, decay times and smoothed frequency response. Tick several to overlay their responses, and read the octave-band RT60 values side by side in the list or the CSV. Phone microphones roll off at the frequency extremes, so compare measurements made with the same device and position, and read differences rather than absolute response.
Room modes and treatment
The mode calculator lists axial, tangential and oblique modes of a rectangular room up to 200 Hz from its length, width and height, and flags axial modes that pile up within 5 % of each other or leave wide gaps. With a measured RT60 it also gives the Schroeder frequency, below which modes rather than reverberation dominate. Treatment suggestions compare the mid-band RT60 with a target for the room use and estimate the extra absorption with the Sabine equation, plus advice on bass traps when the low bands ring much longer. They are not an acoustic design, and real absorbers vary a lot by thickness and mounting.
Exemple resolt
A podcaster measures a 5.0 × 4.0 × 2.5 m spare room with a 5-second sweep from 40 Hz to 16 kHz. The tool reports T30 of 0.82 s broadband, with 0.95 s at 125 Hz and 0.78 s at 1 kHz, and a 52 dB decay range. For a voice booth target of 0.2-0.35 s it estimates about 18.6 m² of extra absorption, roughly 29 panels of 0.72 m². After hanging 12 panels and a rug she measures again: T30 falls to 0.41 s, and the overlaid frequency responses show the 34 Hz and 69 Hz axial modes still standing out, so bass traps are next.
En resum
- Categoria: Àudio, vídeo i disseny
- S'executa al navegador, sense registre, sense pujar res.
- La informació que introdueixes es queda al dispositiu.
- Disponible en anglès.
- Contingut revisat per última vegada:
- Font oficial: ISO 3382-2:2008 reverberation time measurement
Preguntes freqüents
What is RT60?
The time it takes for sound to fall by 60 dB after the source stops. Small treated rooms are around 0.2 to 0.4 s, living rooms 0.4 to 0.6 s, and large halls well above a second.
Why are T20 and T30 different?
Both fit a line to part of the decay (−5 to −25 dB and −5 to −35 dB) and extrapolate to 60 dB. If the decay is not a straight line, for example in coupled spaces, they differ. EDT uses the first 10 dB and relates to how reverberant the room sounds.
Can I use my phone's speaker?
It works for mid and high bands, but phone speakers produce almost no bass, so the 125 and 250 Hz results will be unreliable. A proper loudspeaker gives better low-frequency results.
Why does it say the decay range was too small?
The sweep was not loud enough above the room noise, or the recording clipped. Turn the speaker up a little, reduce noise, or use a longer sweep, which gains signal-to-noise.
Is this a certified measurement?
No. It follows the same method, but with an uncalibrated microphone and speaker, and it does not check the full ISO 3382 requirements for positions and equipment.
Can I measure with a separate recorder?
Yes. Download the sweep WAV, play it on any system, record with any recorder, and import the recording with the same sweep settings.