Pile Capacity Calculator

Enter pile diameter and length with soil strength or friction parameters to get shaft and base resistance, ultimate and allowable capacity, or the efficiency of a pile group.

S'executa al teu navegador. Els fitxers mai no surten del dispositiu. Mira com comprovar-ho

…

Com es fa

  1. 1
    Choose the soil

    Clay, sand or group.

  2. 2
    Enter pile size

    Diameter and embedded length.

  3. 3
    Add soil parameters

    cu, γ′, β and Nq.

  4. 4
    Set the safety factor

    For the allowable load.

  5. 5
    Read capacities

    Shaft, base and total.

Sobre aquesta eina

A pile carries load by friction along its shaft and by bearing at its base. In clay, shaft friction is usually estimated with the alpha (total stress) method: fs = α·cu, where the adhesion factor α falls as the clay gets stronger relative to the overburden pressure. The base resistance in clay is about 9·cu. In sand, the beta (effective stress) method gives fs = β·σ′v along the shaft and q = Nq·σ′v at the base, often with limiting values. This calculator applies both methods for a pile in a single layer, gives the ultimate capacity and the allowable load with your factor of safety, and a group mode estimates the efficiency of a rectangular pile group with the Converse-Labarre formula.

Who this is for

Geotechnical and structural engineers, piling contractors, students and engineers making preliminary designs.

Clay: alpha method

- Mean vertical effective stress at mid-length: σ′v = γ′·L/2. - API RP 2GEO: ψ = cu/σ′v; α = 0.5·ψ^−0.5 for ψ ≤ 1, 0.5·ψ^−0.25 for ψ > 1, at most 1. - Shaft resistance Qs = α·cu·π·D·L. - Base resistance Qb = 9·cu·π·D²/4.

Sand: beta method

- Shaft friction fs = β·σ′v, with β typically 0.25-0.4 for bored piles and 0.3-0.8 for driven displacement piles. - Base resistance q = Nq·σ′v at the toe, with Nq from 20 to 60 depending on the friction angle and installation, often limited to 5-12 MPa. Values depend strongly on installation method; use local correlations or load tests.

Factor of safety

Working stress design often uses a global factor of 2 to 3 on the ultimate capacity. Eurocode 7 instead applies partial factors and model factors and rewards load testing.

Group efficiency

Piles close together interact. The Converse-Labarre formula gives η = 1 − θ·[(n − 1)m + (m − 1)n]/(90·m·n), with θ = atan(D/s) in degrees. A 3 × 3 group of 0.6 m piles at 1.8 m spacing has η = 73 %. Groups in sand driven at normal spacing often show efficiencies near or above 1; in clay, block failure must also be checked.

Worked example

A 0.6 m bored pile, 15 m long in clay with cu = 50 kPa and γ′ = 8 kN/m³: σ′v = 60 kPa, α = 0.55, Qs = 774 kN, Qb = 127 kN, ultimate 902 kN and allowable 361 kN with FS = 2.5.

Example uses

A designer compares a 0.6 m and a 0.75 m pile for a bridge pier.

Limits

Single homogeneous layer, axial compression only; negative skin friction, settlement, tension and lateral loads are not checked. This is not professional engineering advice.

Exemple resolt

0.6 m pile, 15 m in clay with cu 50 kPa: ultimate 902 kN, allowable 361 kN at FS 2.5.

En resum

Preguntes freqüents

What is the alpha method?

A total stress method where shaft friction equals α times the undrained shear strength.

What is the beta method?

An effective stress method where shaft friction equals β times the vertical effective stress.

Why is end bearing in clay 9·cu?

It is the bearing capacity factor Nc for deep foundations.

What factor of safety is used?

Often 2 to 3 on the ultimate capacity.

Do pile groups carry less than single piles?

In clay often yes; in sand the efficiency can be close to 1.

Is my data stored?

No. Clearing the page clears everything.

Totalment gratisSense cost, sense registre
Els fitxers es mantenen privatsTot funciona al teu navegador
Fàcil en el teu idiomaDisponible en molts idiomes