ISO 4406 Oil Cleanliness Code Calculator
Enter particle counts per mL or per 100 mL at 4, 6 and 14 µm(c) from a lab report or particle counter, get the ISO 4406 code and check it against your target cleanliness.
S'executa al teu navegador. Els fitxers mai no surten del dispositiu. Mira com comprovar-ho
…
Com es fa
- 1Choose the count basis
Per mL or per 100 mL.
- 2Enter the three counts
At 4, 6 and 14 µm(c).
- 3Enter your target code
From the component maker.
- 4Read the ISO code
R4/R6/R14.
- 5Check the gap
The reduction factor needed.
Sobre aquesta eina
Solid particles cause most hydraulic failures: they wear pumps, jam valves and score cylinders. ISO 4406 describes the contamination of a fluid with three scale numbers, one each for particles larger than 4, 6 and 14 µm(c), written as 18/16/13. Each step up the scale doubles the number of particles. This calculator converts counts per mL or per 100 mL into the three scale numbers using the ISO 4406 table, compares the result with a target code for your system, and shows the factor by which contamination must be reduced to reach it. It also flags counts that are not in descending order, which usually points to a reporting error.
Who this is for
Maintenance and reliability engineers, lubrication technicians, hydraulic system builders, oil analysis labs and fleet managers.
How the code works
The scale numbers come from ranges of particles per mL. Each range doubles: scale 13 covers more than 40 up to 80 particles per mL, scale 14 more than 80 up to 160, scale 16 more than 320 up to 640, and scale 18 more than 1,300 up to 2,500. Codes are reported as R4/R6/R14.
Typical target codes
| System | Target | |---|---| | Servo and proportional valves | 16/14/11 to 17/15/12 | | High-pressure piston pumps (over 250 bar) | 17/15/12 | | Industrial gear and vane pumps | 18/16/13 to 19/17/14 | | Low-pressure systems, mobile hydraulics | 19/17/14 to 20/18/15 | | New oil from the drum (typical) | 20/18/15 to 22/20/17 | Component makers specify their own limits; use the strictest one in the circuit.
Why one step matters
Each scale number doubles the particle count. Lowering the code from 19/17/14 to 16/14/11 means eight times fewer particles, and studies by filter makers show it can multiply component life several times.
Sampling
Take samples from a running system at a turbulent point, such as a dedicated sampling valve on the return line before the filter. Flush the valve first and use certified clean bottles. Bad sampling is the most common cause of wrong codes.
Worked example
Counts of 2,000, 450 and 60 particles per mL at 4, 6 and 14 µm(c) give code 18/16/13. Against a target of 17/15/12, every size is one step too high, so contamination must be halved.
Example uses
A maintenance team trends the code of a press every month and changes filters when it rises two steps. A buyer checks that new oil meets the cleanliness promised by the supplier.
Limits
Assumes automatic particle counter results calibrated to ISO 11171 (µm(c)). Microscope counts under ISO 4407 report only the 5 and 15 µm sizes. This is not professional engineering advice.
Exemple resolt
2,000, 450 and 60 particles per mL give ISO 4406 code 18/16/13.
En resum
- Categoria: Enginyeria i construcció
- S'executa al navegador, sense registre, sense pujar res.
- La informació que introdueixes es queda al dispositiu.
- Disponible en anglès.
- Contingut revisat per última vegada:
- Font oficial: ISO 4406:2021 Hydraulic fluid power: code for defining the level of contamination by solid particles
Preguntes freqüents
What does 18/16/13 mean?
Scale numbers for particles above 4, 6 and 14 µm(c).
How much dirtier is one code step?
Twice as many particles.
What target should I use for servo valves?
Usually 16/14/11 or 17/15/12, as specified by the valve maker.
Is new oil clean?
Often not: drum oil is frequently 20/18/15 or worse.
What is µm(c)?
Particle size calibrated to ISO 11171 for automatic counters.
Is my data stored?
No. Lab results you enter stay on this device.