Control Chart Limits Calculator

Choose a chart, enter the grand mean and average range or standard deviation, the average proportion or count, or paste individual values, and get the centre line and 3-sigma limits.

S'executa al teu navegador. Els fitxers mai no surten del dispositiu. Mira com comprovar-ho

…

Com es fa

  1. 1
    Choose the chart

    Variables or attributes.

  2. 2
    Enter the base statistics

    Means, ranges or proportions.

  3. 3
    Set the subgroup size

    2 to 10 for X̄ charts.

  4. 4
    Or paste values

    For individuals charts.

  5. 5
    Read the limits

    Centre line, UCL and LCL.

Sobre aquesta eina

Control charts separate the normal, common-cause variation of a process from special causes that need action. Each chart has a centre line and upper and lower control limits at about three standard deviations, calculated from the process itself, not from the specification. This calculator covers the seven classic Shewhart charts. For variables, X̄-R and X̄-S charts use subgroups of 2 to 10 with the tabulated constants A2, D3, D4, d2, A3, B3, B4 and c4, and the individuals and moving range chart works from pasted values. For attributes, p and np charts handle proportions defective, and c and u charts handle counts of defects.

Who this is for

Quality engineers and technicians, production supervisors, Six Sigma practitioners, laboratory managers and students.

Choosing the chart

| Data | Subgroup | Chart | |---|---|---| | Measurements | 2-10 | X̄-R | | Measurements | more than 10 or variable | X̄-S | | Measurements | 1 | I-MR | | Defective units, varying n | any | p | | Defective units, constant n | any | np | | Defects, constant area | 1 unit | c | | Defects, varying area | any | u |

Formulas

- X̄-R: UCL/LCL = X̿ ± A2·R̄; R chart limits D3·R̄ and D4·R̄; σ = R̄/d2. - X̄-S: X̿ ± A3·s̄; S chart limits B3·s̄ and B4·s̄; σ = s̄/c4. - I-MR: X̄ ± 2.66·MR̄; MR chart UCL = 3.267·MR̄. - p: p̄ ± 3·√(p̄(1 − p̄)/n); np: n·p̄ ± 3·√(n·p̄(1 − p̄)). - c: c̄ ± 3·√c̄; u: ū ± 3·√(ū/n). Negative lower limits are set to zero.

Constants

| n | A2 | D3 | D4 | d2 | |---|---|---|---|---| | 2 | 1.880 | 0 | 3.267 | 1.128 | | 3 | 1.023 | 0 | 2.574 | 1.693 | | 4 | 0.729 | 0 | 2.282 | 2.059 | | 5 | 0.577 | 0 | 2.114 | 2.326 | | 10 | 0.308 | 0.223 | 1.777 | 3.078 |

Reading the chart

Investigate when a point falls outside the limits, or when patterns appear: seven or more points in a row on one side of the centre, six rising or falling in a row, or two of three points beyond two sigma (Western Electric rules).

Worked example

X̄-R with X̿ = 50.0, R̄ = 2.0 and n = 5: X̄ limits 48.85 to 51.15, R chart up to 4.23, and estimated σ = 0.86.

Common mistakes

- Using specification limits as control limits. - Recalculating limits after every point, which hides drifts. - Mixing different machines or materials in one subgroup.

Example uses

A machining cell tracks shaft diameters in subgroups of five. A laboratory plots daily check-standard results on an I-MR chart. A packaging line follows the fraction of rejected cartons on a p chart.

Limits

Limits assume a stable process during the base period, typically 20-25 subgroups. This is not professional advice.

Exemple resolt

X̿ 50.0, R̄ 2.0, subgroups of 5: X̄ chart limits 48.85 to 51.15, R chart UCL 4.23.

En resum

Preguntes freqüents

Are control limits the same as specification limits?

No. Control limits come from the process; specifications come from the customer.

Which chart do I use for single measurements?

The individuals and moving range (I-MR) chart.

How many subgroups do I need?

About 20 to 25 to set reliable limits.

When do I use a p chart?

For the proportion of defective units in samples.

What is d2?

The constant linking the average range to sigma for a subgroup size.

Is my data stored?

No, everything is calculated on this page.

Totalment gratisSense cost, sense registre
Els fitxers es mantenen privatsTot funciona al teu navegador