Atterberg Limits Test Sheet (Liquid and Plastic Limit)
Record liquid limit trials by the Casagrande cup (multipoint or one-point) or the cone penetrometer and plastic limit trials from moisture tins, and get moisture contents, the flow curve with the liquid limit at 25 blows, the plastic limit, plasticity index, liquidity and consistency index, activity and the plasticity chart class in USCS, BS 5930 or IS 1498 terms.
S'executa al teu navegador. Els fitxers mai no surten del dispositiu. Mira com comprovar-ho
…
Com es fa
- 1Choose the method
Select the multipoint cup, the one-point cup or the cone penetrometer and the plasticity terms.
- 2Enter liquid limit trials
For each trial type the blows or penetration and the three tin weighings.
- 3Enter plastic limit trials
Add the tin weighings for each rolled thread trial.
- 4Add natural moisture
Type the natural moisture content and the clay fraction for LI, CI and activity.
- 5Check the curves
Look at the flow curve fit and the plasticity chart, and heed any warnings.
- 6Print the sheet
Print the full test sheet or export CSV for the lab records.
Sobre aquesta eina
The Atterberg limits describe how a fine-grained soil changes from a liquid to a plastic to a semi-solid state as it dries. The liquid limit is the moisture content at which the soil starts to flow, and the plastic limit is the moisture content at which a thread of soil rolled to 3 mm crumbles. The difference, the plasticity index, is one of the most used numbers in geotechnical engineering: it classifies clays and silts, predicts shrink and swell behaviour and enters many correlations for strength and compressibility. Each trial starts with a moisture tin: the tin mass, the tin with wet soil and the tin with oven-dried soil give the water content w = (wet − dry) / (dry − tin) × 100. In the Casagrande multipoint method the cup is dropped until the groove closes over 13 mm, the blow count is recorded and a moisture sample is taken, for three or more trials between about 15 and 35 blows. The tool fits a straight line of moisture against the logarithm of blows and reads the liquid limit at 25 blows; the slope of that line is the flow index. The one-point method uses a single trial between 20 and 30 blows and a correction formula, either the ASTM D4318 method B factor (N / 25)^0.121 or the IS 2720 Part 5 form w / (1.3215 − 0.23 log N). With the cone penetrometer, preferred in BS 1377, the liquid limit is the moisture at 20 mm penetration on a straight-line fit. The plastic limit is the average of the thread trials, and the sheet flags trials that differ by more than about 1.4 percentage points.
Indices and the plasticity chart
Enter the natural moisture content to get the liquidity index LI = (wn − PL) / PI with a consistency description, and the consistency index CI = (LL − wn) / PI. With the clay fraction finer than 2 µm the activity PI / clay percent rates the clay as inactive, normal or active. The plasticity chart plots the sample against the A-line PI = 0.73 (LL − 20) and the U-line PI = 0.9 (LL − 8), and gives the USCS group (CL, ML, CH, MH or CL-ML), the BS 5930 class (CL, CI, CH, CV, CE and the M equivalents) or the IS 1498 class (L, I, H).
Reporting
Results show the computed limits to one decimal and the rounded whole numbers that the standards ask you to report. Print the full sheet with both tables, the flow curve and the chart, or export CSV.
Limits
The calculations depend on the way the sample was prepared (air-dried or natural, passing the 425 µm sieve), mixing and curing time and the device used, which the tool cannot check. Organic soils need the oven-dried liquid limit as well, which is not handled automatically. Points above the U-line usually mean a test error. Verify with a qualified engineer.
Exemple resolt
A clay sample from a borehole at 3 m gives four cup trials at 34, 26, 19 and 14 blows with moisture contents of 38.47, 40.99, 43.58 and 45.90 percent. The flow curve has R² = 0.998, a flow index of 19.2 and a liquid limit of 41.2 percent, reported as 41. Two plastic limit threads give 19.40 and 19.54 percent, an average of 19.5, reported as 19, so the plasticity index is 21.7 (22 from the rounded values). With a natural moisture content of 28 percent the liquidity index is 0.39 (stiff to firm) and the consistency index 0.61. A clay fraction of 22 percent gives an activity of 0.99, normal clay. The point lies above the A-line at LL 41, so the USCS group is CL, lean clay, and in BS 5930 terms CI, clay of intermediate plasticity.
En resum
- Categoria: Enginyeria i construcció
- S'executa al navegador, sense registre, sense pujar res.
- La informació que introdueixes es queda al dispositiu.
- Disponible en anglès.
- Contingut revisat per última vegada:
- Font oficial: ASTM D4318, BS 1377-2:1990 clauses 4 and 5, IS 2720 (Part 5), ASTM D2487 plasticity chart, BS 5930 and IS 1498 plasticity terms
Preguntes freqüents
How is the liquid limit found from the flow curve?
Plot moisture content against the number of blows on a log scale for three or more trials, draw the best straight line and read the moisture at 25 blows. The tool fits the line by least squares and also gives the flow index.
When can I use the one-point method?
When a single trial closes the groove between 20 and 30 blows; ASTM prefers 22 to 28. The moisture is corrected to 25 blows with a standard factor. It is quicker but less reliable than the multipoint method.
What is the difference between the cup and the cone method?
The Casagrande cup counts blows to close a groove, while the cone penetrometer measures how far a standard cone sinks in 5 seconds; the liquid limit is the moisture at 20 mm penetration. BS 1377 prefers the cone because it is less dependent on the operator.
What does the plasticity index tell me?
PI is the range of moisture over which the soil behaves plastically. Low PI soils are silty and lose strength quickly when wet; high PI clays shrink and swell strongly with changes in moisture.
What if the soil will not roll into a thread?
Then the plastic limit cannot be determined and the soil is reported as non-plastic (NP). Tick the non-plastic box and the tool reports PI as NP.
Which classification should I use?
Use USCS for ASTM-based projects, BS 5930 terms in the UK and IS 1498 in India. The tool plots the same point on the chart and names it in the system you choose.